The Effect of a Fluorophore Photo-Physics on the Lipid Vesicle Diffusion Coefficient Studied by Fluorescence Correlation Spectroscopy

被引:0
作者
Dominik Drabik
Magda Przybyło
Aleksander Sikorski
Marek Langner
机构
[1] Wroclaw University of Technology,Laboratory for Biophysics of Macromolecular Aggregates, Department of Biomedical Engineering
[2] Lipid Systems sp. z. o. o. [Ltd],Laboratory of Cytobiochemistry, Faculty of Biotechnology
[3] University of Wroclaw,undefined
来源
Journal of Fluorescence | 2016年 / 26卷
关键词
Fluorescence correlation spectroscopy; Dynamic light scattering; Photo-bleaching; Blinking; Fluorescent probes;
D O I
暂无
中图分类号
学科分类号
摘要
Fluorescence Correlation Spectroscopy (FCS) is a technique, which allows determination of the diffusion coefficient and concentration of fluorescent objects suspended in the solution. The measured parameter is the fluctuation of the fluorescence signal emitted by diffusing molecules. When 100 nm DOPC vesicles labeled with various fluorescent dyes (Fluorescein-PE, NBD-PE, Atto488 DOPE or βBodipy FL) were measured, different values of diffusion coefficients have been obtained. These diffusion coefficients were different from the expected values measured using the dynamic light scattering method (DLS). The FCS was initially developed for solutions containing small fluorescent molecules therefore the observed inconsistency may result from the nature of vesicle suspension itself. The duration of the fluorescence signal may depend on the following factors: the exposure time of the labeled object to the excitation beam, the photo-physical properties (e.g., stability) of a fluorophore, the theoretical model used for the calculations of the diffusion coefficient and optical properties of the vesicle suspension. The diffusion coefficients determined for differently labeled liposomes show that its dependence on vesicle size and quantity of fluorescent probed used for labeling was significant demonstrating that the fluorescence properties of the fluorophore itself (bleaching and/or blinking) were critical factors for a correct outcome of FCS experiment. The new, based on combined FCS and DLS measurements, method for the determination of the focal volume prove itself to be useful for the evaluation of a fluorescence dye with respect to its applicability for FCS experiment.
引用
收藏
页码:661 / 669
页数:8
相关论文
共 90 条
[1]  
Fitzpatrick JAJ(2011)Fluorescence correlation spectroscopy: linking molecular dynamics to biological function in vitro and in situ Curr Opin Struct Biol 21 650-660
[2]  
Lillemeier BF(2003)Statistical analysis of fluorescence correlation spectroscopy: the standard deviation and bias Biophys J 84 2030-2042
[3]  
Saffarian S(2009)Quantitative FCS: determination of the confocal volume by FCS and bead scanning with the MicroTime 200 Application Note: Quantitative FCS 1 1-8
[4]  
Elson EL(2007)Fluorescence correlation spectroscopy, an introduction to its concepts and applications Annu Rev Biophys Biomol Struct 36 151-169
[5]  
Buschmann V(2011)Fluorescence correlation spectroscopy in biology, chemistry, and medicine Biochem Mosc 76 497-516
[6]  
Kramer B(2009)Fluorescence correlation spectroscopy in membrane structure elucidation Biochim Biophys Acta 1788 225-233
[7]  
Koberling F(2012)Fluorescence correlation spectroscopy in colloid and interface science Curr Opin Colloid In 17 377-387
[8]  
Macdonald R(2011)The effect of variable liposome brightness on quantifying lipid-protein interactions using fluorescence correlation spectroscopy Biochim Biophys Acta 1808 2559-2568
[9]  
Ruttinger S(2010)Quantitative assesment of peptide-lipid interactions. Ubiquitous fluorescence methodologies Biochim Biophys Acta 1798 1999-2012
[10]  
Schwille P(1985)Production of large unilamellar vesicles by a rapid extrusion procedure Biochim Biophys Acta 812 55-65