Psychophysical Tuning Curves as a Correlate of Electrode Position in Cochlear Implant Listeners

被引:0
作者
Lindsay DeVries
Julie G. Arenberg
机构
[1] University of Washington,Department of Speech and Hearing Sciences
来源
Journal of the Association for Research in Otolaryngology | 2018年 / 19卷
关键词
psychophysical tuning curves; cochlear implants; electrode position; imaging; psychophysics;
D O I
暂无
中图分类号
学科分类号
摘要
Speech understanding abilities vary widely among cochlear implant (CI) listeners. A potential source of this variability is the electrode-neuron interface (ENI), which includes peripheral factors such as electrode position and integrity of remaining spiral ganglion neurons. Suboptimal positioning of the electrode array has been associated with poorer speech outcomes; however, postoperative computerized tomography (CT) scans are often not available to clinicians. CT-estimated electrode-to-modiolus distance (distance from the inner wall of the cochlea) has been shown to account for some variability in behavioral thresholds. However, psychophysical tuning curves (PTCs) may provide additional insight into site-specific variation in channel interaction. Thirteen unilaterally implanted adults with the Advanced Bionics HiRes90K device participated. Behavioral thresholds and PTCs were collected for all available electrodes with steered quadrupolar (sQP) configuration, using a modified threshold sweep procedure, used in Bierer et al. (Trends Hear 19:1–12, 2015). PTC bandwidths were quantified to characterize channel interaction across the electrode array, and tip shifts were assessed to identify possible contributions of neural dead regions. Broader PTC bandwidths were correlated with electrodes farther from the modiolus, but not correlated with sQP threshold, though a trend was observed. Both measures were affected by scalar location, and PTC tip shifts were observed for electrodes farther from the modiolus. sQP threshold was the only variable correlated with word recognition. These results suggest PTCs may be used as a site-specific measure of channel interaction that correlates with electrode position in some CI listeners.
引用
收藏
页码:571 / 587
页数:16
相关论文
共 156 条
[1]  
Abbas PJ(2004)Channel interaction in cochlear implant users evaluated using the electrically evoked compound action potential Audiol Neurotol 9 203-213
[2]  
Hughes ML(2011)Comparing spatial tuning curves, spectral ripple resolution, and speech perception in cochlear implant users J Acoust Soc Am 130 364-375
[3]  
Brown CJ(2007)Quality control after insertion of the nucleus contour and contour advance electrode in adults Ear Hear 28 75S-79S
[4]  
Anderson ES(2008)Mixed-effects modeling with crossed random effects for subjects and items J Mem Lang 59 390-412
[5]  
Nelson DA(2010)Probing the electrode-neuron Interface with focused Cochlear implant stimulation Trends in Amplif 14 84-95
[6]  
Kreft H(2007)Threshold and channel interaction in cochlear implant users: evaluation of the tripolar electrode configuration J Acoust Soc Am 121 1642-1653
[7]  
Aschendorff A(2015)A fast method for measuring psychophysical thresholds across the cochlear implant Array Trends Hear 19 1-12
[8]  
Kromeier J(2010)Partial tripolar cochlear implant stimulation: spread of excitation and forward masking in the inferior colliculus Hear Res 270 134-142
[9]  
Klenzner T(2010)Identifying cochlear implant channels with poor electrode-neuron interface: partial tripolar, single-channel thresholds and psychophysical tuning curves Ear Hear 31 247-47
[10]  
Laszig R(2013)Factors affecting auditory performance of postlinguistically deaf adults using cochlear implants: an update with 2251 patients Audiol Neurotol 18 36-27