Comparison of the material properties of PMMA and glass-ionomer based cements for use in orthopaedic surgery

被引:0
作者
W. A. J. Higgs
P. Lucksanasombool
R. J. E. D. Higgs
M. V. Swain
机构
[1] Unversity of Sydney,Biomaterials Research Unit, Faculty of Dentistry
[2] University of Sydney,Biomedical Engineering Group, Department of Mechanical Engineering
[3] University of Sydney,Faculty of Medicine
[4] University of Sydney,Biomedical Engineering Group, Department of Mechanical Engineering
[5] Concord Repatriation General Hospital,Department of Orthopaedic Surgery
来源
Journal of Materials Science: Materials in Medicine | 2001年 / 12卷
关键词
Compressive Strength; Fracture Toughness; PMMA; Bone Cement; HEMA;
D O I
暂无
中图分类号
学科分类号
摘要
The intrisic benefits of low exotherm and bioactivity have generated interest in utilizing glass-ionomer cements (GIC) as a bone cement replacement in orthopaedic surgery. This paper is concerned with evaluating the mechanical properties of compressive strength, flexural strength, and fracture toughness for two traditional GICs, one resin-modified GIC (an experimental bone cement) and two polymethylmethacrylate (PMMA) cement systems. To determine the suitability of a GIC system for use in the clinical orthopaedic setting, the additional characteristics of setting exotherm and setting time have also been evaluated. The characterization of these two vastly different cement systems has raised some concern as to the applicability of using the current orthopaedic standards for the testing of GIC systems. In particular, issues relating to the strain rate dependence of PMMA cement and the exothermic basis for determining setting time are not applicable as these factors are not characteristic of GIC systems. Whilst the intrinsic benfits of current GIC systems are well understood and generally accepted, this study has shown their intrinsic mechanical properties to be inferior to current PMMA cements. Improvement in the mechanical properties of traditional GICs have been achieved with the addition of a resin component (HEMA). © 2001 Kluwer Academic Publishers
引用
收藏
页码:453 / 460
页数:7
相关论文
共 136 条
[1]  
Black B.(1970)undefined Clin. Orthop. Rela. Res 72 239-undefined
[2]  
Haven J. K.(1969)undefined Clin. Orthop. Rela. Research 67 169-undefined
[3]  
Hastings G. W.(1960)undefined J. Bone Joint Surg. 42B 28-undefined
[4]  
Homsy C. A.(1984)undefined J. Biomed. Mater. Res. 8 435-undefined
[5]  
Tullos H. S.(1980)undefined Biomater. Sci. 208 826-undefined
[6]  
King J. W.(1990)undefined Clin. Mater. 6 323-undefined
[7]  
Charnley J.(1989)undefined Clin. Mater. 4 85-undefined
[8]  
Saha S.(1989)undefined Clin. Mater. 4 201-undefined
[9]  
Pal S.(1991)undefined Clin. Mater. 8 125-undefined
[10]  
Hench L. L.(1999)undefined J. Bone Joint Surg. 81B–S1 18-undefined