Monitoring of (bio)available labile metal fraction in a drinking water treatment plant by diffusive gradients in thin films

被引:0
作者
Alfredo Díaz
Rebeca Arnedo
Raquel Céspedes-Sánchez
Ricard Devesa
Jordi Martin-Alonso
机构
[1] Societat General d’Aigües de Barcelona,AGBAR
[2] S.A.,undefined
[3] CETaqua,undefined
[4] Water Technology Center,undefined
来源
Environmental Monitoring and Assessment | 2012年 / 184卷
关键词
Drinking water; Diffusive gradients in thin films; Labile metal specie; Drinking water treatment plant;
D O I
暂无
中图分类号
学科分类号
摘要
A performance study of diffusive gradients in thin films (DGT) and inductively coupled plasma optical emission spectrometry (ICP-OES) was applied for the monitoring of the labile fraction of metals Al, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb and Zn, in Sant Joan Despí Drinking Water Treatment Plant located in the South of Barcelona’s Metropolitan Area (Spain). The DWTP monitoring protocol was optimized by working for 1 day of deployment (24 h) with the DGT device in contact with both treated and river water matrixes. Additionally, it was demonstrated that an increase in the deployment time of 1 week did not decrease the evaluated concentrations of the studied metals. The quality parameters of the DGT device and ICP-OES determination, such as limit of quantification, accuracy expressed as relative error (%) and reproducibility expressed as relative standard deviation, were evaluated. Good results were obtained for all the metals in ultrapure water; limits of quantification ranged from 1.5 μg L − 1 for cadmium to 28 μg L − 1 for zinc when deployment time of 24 h was used and from 0.2 μg L − 1 for cadmium to 4 μg L − 1 for zinc when this time was increased by 1 week. Accuracy and precisions lower than or equal to 10% were obtained at a parametric concentration value of the metals regulated in the European Drinking Water Guidelines (98/83/EC). DGT deployment was tested in river and treated water, and good results were obtained for Cd, Ni, Co and Zn, whereas for the other metals, a continuous control of their metallic labile fractions was monitored. Therefore, DGT device allows the continuous monitoring of the labile metal species in a drinking water treatment plant.
引用
收藏
页码:539 / 548
页数:9
相关论文
共 93 条
[1]  
Allan IJ(2007)Chemcatcher® and DGT passive sampling devices for regulatory monitoring of trace metals in surface water Journal of Environmental Monitoring 9 672-undefined
[2]  
Knutsson J(2006)A “toolbox” for biological and chemical monitoring requirements of the European Union’s Water Framework Directive Talanta 69 302-undefined
[3]  
Guigues N(2008)Inputs of total and labile trace metals from wastewater treatment plants effluents to the Seine River Physics and Chemistry of the Earth 65 2419-undefined
[4]  
Mills GA(2006)Trace metal speciation and fluxes within a major French wastewater treatment plant: Impact of the successive treatments stages Chemosphere 358 277-undefined
[5]  
Fouillac AM(2006)Evaluation of DGT as a metal speciation tool in wastewater The Science of the Total Environment 56 148-undefined
[6]  
Greenwood R(2003)Elemental speciation studies—new directions for trace metal analysis Ecotoxicology and Environmental Safety 48 353-undefined
[7]  
Allan IJ(2007)Theory and applications of DGT measurements in soils and sediments Comprehensive Analytical Chemistry 239 71-undefined
[8]  
Vrana B(1999)In situ measurements of labile Cu, Cd and Mn in river waters using DGT The Science of the Total Environment 387 2239-undefined
[9]  
Greenwood R(2007)Use of the diffusive gradients in thin films technique to evaluate (bio)available trace metal concentrations in river water Analytical and Bioanalytical Chemistry 159 99-undefined
[10]  
Mills GA(2009)Preliminary assessment of total dissolved trace metal concentration in Sava River water Environmental Monitoring and Assessment 40 3901-undefined