Prompt gamma-ray neutron activation analysis of boron using Deuterium–Deuterium (D–D) neutron generator

被引:0
作者
K. Bergaoui
N. Reguigui
C. K. Gary
C. Brown
J. T. Cremer
J. H. Vainionpaa
M. A. Piestrup
机构
[1] National Center of Nuclear Sciences and Technologies,Unité de recherche “Maîtrise et Développement des Techniques Nucléaires à Caractère Pacifique”
[2] Adelphi Technology Inc.,undefined
来源
Journal of Radioanalytical and Nuclear Chemistry | 2015年 / 303卷
关键词
PGNAA; D–D neutron generator; HPGe detector; NaI detector; Boron; MCNP6;
D O I
暂无
中图分类号
学科分类号
摘要
Prompt gamma-ray neutron activation analysis (PGNAA) is a nuclear analytical technique for the determination of trace and other elements in solid, liquid or gaseous samples. The method consists in observing gamma rays emitted by a sample during neutron irradiation. The PGNAA system was built using a moderated and shielded deuterium–deuterium (D–D) neutron generator. This facility has been developed to determine the chemical composition of materials. The neutron generator is composed of three major components: An RF-Induction Ion Source, the Secondary Electron Shroud, and the Diode Accelerator Structure and Target. The generator produces monoenergetic neutrons (2.5 MeV) with a yield of 1010 n/s using 25–50 mA of beam current and 125 kV of acceleration voltage. Prompt γ-ray neutron activation analysis of 10B concentrations in Si and SiO2 matrices was carried out using a germanium detector (HPGe) and the results obtained are compared with a PGNAA system using a NaI detector. Neutron flux and energy distribution from D–D neutron generator at the sample position was calculated using Monte Carlo simulation. The interaction properties of neutrons in a Germanium detector have been studied.
引用
收藏
页码:115 / 121
页数:6
相关论文
共 53 条
[1]  
Ellis KJ(1993)In-vivo activation analysis: present and future prospects J Radioanal Nucl Chem 169 291-300
[2]  
Spyrou NM(1999)Neutron activation analysis challenges: problems and applications in biomedical and other areas J Radioanal Nucl Chem 239 59-70
[3]  
Kudějová P(2005)On the construction of a new instrument for cold-neutron prompt gamma-ray activation analysis at the FRM-II J Radioanal Nucl Chem 265 221-227
[4]  
Park YJ(2004)A neutron induced prompt gamma-ray spectroscopy system using a  J Radioanal Nucl Chem 260 585-594
[5]  
Song BC(2004)Cf neutron source for quantitative analysis of aqueous samples J Radioanal Nucl Chem 262 661-664
[6]  
Chowdhury MI(2008)Prompt gamma neutron activation analysis of boron with a J Radioanal Nucl Chem 276 71-77
[7]  
Jee KY(1997)Am-Be neutron source J Radioanal Nucl Chem 216 191-198
[8]  
Turhan Ş(1976)Prompt-gamma neutron activation analysis system design: effects of D-T versus D-D neutron generator source selection Int Appl Radiat Isot 27 689-693
[9]  
Yücel H(2009)Optimization of PGNAA instrument design for cement raw materials using the MCNP code J Radioanal Nucl Chem 281 291-294
[10]  
Demirbaş A(2002)Prompt gamma-ray analysis using 329 MeV neutron inelastic scattering Nucl Instrum Methods A 488 410-418