Do design variations in the artificial disc influence cervical spine biomechanics? A finite element investigation

被引:5
作者
Ahmad Faizan
Vijay K. Goel
Steven R. Garfin
Christopher M. Bono
Hassan Serhan
Ashok Biyani
Hossein Elgafy
Manoj Krishna
Tai Friesem
机构
[1] University of Toledo,Engineering Center for Orthopaedic Research Excellence (E
[2] University of California,CORE), Departments of Bioengineering and Orthopaedic Surgery, 5046 NI, MS 303, Colleges of Engineering and Medicine
[3] San Diego,Department of Orthopaedics
[4] Harvard Medical School,Brigham and Women’s Hospital
[5] DePuy Spine,undefined
[6] The University Hospital of North Tees,undefined
来源
European Spine Journal | 2012年 / 21卷
关键词
Cervical; Disc replacement; Finite element; Biomechanics; Design variation;
D O I
暂无
中图分类号
学科分类号
摘要
Various ball and socket-type designs of cervical artificial discs are in use or under investigation. Many artificial disc designs claim to restore the normal kinematics of the cervical spine. What differentiates one type of design from another design is currently not well understood. In this study, authors examined various clinically relevant parameters using a finite element model of C3–C7 cervical spine to study the effects of variations of ball and socket disc designs. Four variations of ball and socket-type artificial disc were placed at the C5–C6 level in an experimentally validated finite element model. Biomechanical effects of the shape (oval vs. spherical ball) and location (inferior vs. superior ball) were studied in detail. Range of motion, facet loading, implant stresses and capsule ligament strains were computed to investigate the influence of disc designs on resulting biomechanics. Motions at the implant level tended to increase following disc replacement. No major kinematic differences were observed among the disc designs tested. However, implant stresses were substantially higher in the spherical designs when compared to the oval designs. For both spherical and oval designs, the facet loads were lower for the designs with an inferior ball component. The capsule ligament strains were lower for the oval design with an inferior ball component. Overall, the oval design with an inferior ball component, produced motion, facet loads, implant stresses and capsule ligament strains closest to the intact spine, which may be key to long-term implant survival.
引用
收藏
页码:653 / 662
页数:9
相关论文
共 98 条
  • [1] Anderson PARJP(2003)Wear analysis of the Bryan cervical disc prosthesis Spine 28 S186-S194
  • [2] Bryan VE(2004)The Bryan cervical disc: wear properties and early clinical results Spine J 4 303S-309S
  • [3] Carlson CS(2007)Changes in adjacent-level disc pressure and facet joint force after cervical arthroplasty compared with cervical discectomy and fusion J Neurosurg Spine 7 33-39
  • [4] Anderson PA(1997)Uncinate processes and Luschka joints influence the biomechanics of the cervical spine: quantification using a finite element model of the C5–C6 segment J Orthop Res 15 342-347
  • [5] Sasso RC(2003)Biomechanical testing of an artificial cervical joint and an anterior cervical plate J Spinal Disord Tech 16 314-323
  • [6] Rouleau JP(2004)In vitro biomechanics of cervical disc arthroplasty with the ProDisc-C total disc implant Neurosurg Focus 17 E7-E129
  • [7] Carlson CS(2001)Load-sharing between anterior and posterior elements in a lumbar motion segment implanted with an artificial disc Spine 26 E122-261
  • [8] Goffin J(2006)Biomechanics of the C5–C6 spinal unit before and after placement of a disc prosthesis Biomech Model Mechanobiol 5 253-691
  • [9] Chang UK(1998)Prediction of load sharing among spinal components of a C5–C6 motion segment using the finite element approach Spine 23 684-2764
  • [10] Kim DH(2005)Effects of charite artificial disc on the implanted and adjacent spinal segments mechanics using a hybrid testing protocol Spine 30 2755-845