Automated IMRT planning in Pinnacle

被引:37
作者
Kusters, J. M. A. M. [1 ]
Bzdusek, K. [2 ]
Kumar, P. [3 ]
van Kollenburg, P. G. M. [1 ]
Kunze-Busch, M. C. [1 ]
Wendling, M. [1 ]
Dijkema, T. [1 ]
Kaanders, J. H. A. M. [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Radiat Oncol, Postbox 9101, NL-6500 HB Nijmegen, Netherlands
[2] Philips Healthcare, Philips Radiat Oncol Syst, Fitchburg, WI 53711 USA
[3] Philips Elect India Ltd, Philips Innovat Campus, Bangalore, Karnataka, India
关键词
Automated planning; Intensity-modulated radiotherapy; Head and neck cancer; Treatment planning; Auto-Planning; MODULATED ARC THERAPY; TREATMENT PLANS; NECK-CANCER; HEAD; QUALITY; RADIOTHERAPY; CONFORMITY; PLANNERS; PROSTATE; INDEX;
D O I
10.1007/s00066-017-1187-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This study evaluates the performance and planning efficacy of the Auto-Planning (AP) module in the clinical version of Pinnacle 9.10 (Philips Radiation Oncology Systems, Fitchburg, WI, USA). Twenty automated intensity-modulated radiotherapy (IMRT) plans were compared with the original manually planned clinical IMRT plans from patients with oropharyngeal cancer. Auto-Planning with IMRT offers similar coverage of the planning target volume as the original manually planned clinical plans, as well as better sparing of the contralateral parotid gland, contralateral submandibular gland, larynx, mandible, and brainstem. The mean dose of the contralateral parotid gland and contralateral submandibular gland could be reduced by 2.5 Gy and 1.7 Gy on average. The number of monitor units was reduced with an average of 143.9 (18%). Hands-on planning time was reduced from 1.5-3 h to less than 1 h. The Auto-Planning module was able to produce clinically acceptable head and neck IMRT plans with consistent quality.
引用
收藏
页码:1031 / 1038
页数:8
相关论文
共 21 条
[1]  
[Anonymous], 2010, J ICRU, V10, P35
[2]   A novel approach to multi-criteria inverse planning for IMRT [J].
Breedveld, Sebastiaan ;
Storchi, Pascal R. M. ;
Keijzer, Marleen ;
Heemink, Arnold W. ;
Heijmen, Ben J. M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (20) :6339-6353
[3]   IMRT dose shaping with regionally variable penalty scheme [J].
Cotrutz, C ;
Xing, L .
MEDICAL PHYSICS, 2003, 30 (04) :544-551
[4]   Volumetric-modulated arc therapy for oropharyngeal carcinoma: A dosimetric and delivery efficiency comparison with static-field IMRT [J].
Dai, Xiaofang ;
Zhao, Yingchao ;
Liang, Zhiwen ;
Dassarath, Meera ;
Wang, Lu ;
Jin, Lihui ;
Chen, Lili ;
Dong, James ;
Price, Robert A. ;
Ma, C-M. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (01) :54-59
[5]   Conformity index:: A review [J].
Feuvret, L ;
Noël, G ;
Mazeron, JJ ;
Bey, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02) :333-342
[6]   Initial evaluation of automated treatment planning software [J].
Gintz, Dawn ;
Latifi, Kujtim ;
Caudell, Jimmy ;
Nelms, Benjamin ;
Zhang, Geoffrey ;
Moros, Eduardo ;
Feygelman, Vladimir .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03) :331-346
[7]   Automatic planning of head and neck treatment plans [J].
Hazell, Irene ;
Bzdusek, Karl ;
Kumar, Prashant ;
Hansen, Christian R. ;
Bertelsen, Anders ;
Eriksen, Jesper G. ;
Johansen, Jorgen ;
Brink, Carsten .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01) :272-282
[8]   Multicriteria optimization enables less experienced planners to efficiently produce high quality treatment plans in head and neck cancer radiotherapy [J].
Kierkels, Roel G. J. ;
Visser, Ruurd ;
Bijl, Hendrik P. ;
Langendijk, Johannes A. ;
van 't Veld, Aart A. ;
Steenbakkers, Roel J. H. M. ;
Korevaar, Erik W. .
RADIATION ONCOLOGY, 2015, 10
[9]   Evaluation of an automated knowledge based treatment planning system for head and neck [J].
Krayenbuehl, Jerome ;
Norton, Ian ;
Studer, Gabriela ;
Guckenberger, Matthias .
RADIATION ONCOLOGY, 2015, 10
[10]  
Kunze-Buch MC, 2007, MEDICAMUNDI, V51, P95