Single-Event Transient Measurements on a DC/DC Pulse Width Modulator Using Heavy Ion, Proton, and Pulsed Laser

被引:0
作者
Y. Ren
A.-L. He
S.-T. Shi
G. Guo
L. Chen
S.-J. Wen
R. Wong
N. W. van Vonno
B. L. Bhuva
机构
[1] University of Saskatchewan,Electrical and Computer Engineering
[2] China Institute of Atomic Energy (CIAE),Electrical Engineering and Computer Science Department
[3] Cisco Systems Inc.,undefined
[4] Intersil Inc.,undefined
[5] Vanderbilt University,undefined
来源
Journal of Electronic Testing | 2014年 / 30卷
关键词
Single-Event Transient (SET); Heavy ion; Proton; Pulsed laser; DC/DC Pulse Width Modulator (PWM);
D O I
暂无
中图分类号
学科分类号
摘要
This paper discusses multiple methods of Single-Event Transient (SET) measurements on a commercial DC/DC Pulse Width Modulator (PWM). Heavy ion, proton, and pulsed laser are used in the experiments. The correlations between the heavy ion, pulsed laser and proton data are analyzed and presented. A proton cross-section model is used to derive proton cross-section from heavy ion test data. The calculated result is close to the real proton data, which means the heavy ion and proton data fit well. The relationship between pulsed laser and proton are also analyzed through heavy as a medium.
引用
收藏
页码:149 / 154
页数:5
相关论文
共 50 条
  • [1] Akkerman A(2002)Nuclear models for proton induced upsets: a critical comparison IEEE Trans Nucl Sci 49 1539-1546
  • [2] Barak J(2000)Empirical modeling of proton induced SEU rates IEEE Trans Nucl Sci 47 545-550
  • [3] Lifshitz Y(2001)Analytical microdosimetrry model for proton-induced SEU in modern devices IEEE Trans Nucl Sci 48 1937-1945
  • [4] Barak J(2006)Simple calculations of proton SEU cross sections from heavy ion cross sections IEEE Trans Nucl Sci 53 3336-3342
  • [5] Barak J(2006)Single-event transients in bipolarlinear integrated circuits IEEE Trans Nucl Sci 53 3079-3102
  • [6] Barak J(2004)Comparison of single-event transients induced in an operational amplifier (LM124) by pulsed laser light and a broad beam of heavy ions IEEE Trans Nucl Sci 51 2776-2781
  • [7] Buchner S(2010)Heavy ion, high-energy, and low-energy proton SEE sensitivity of 90-nm RHBD SRAMs IEEE Trans Nucl Sci 57 3493-3499
  • [8] McMorrow D(1994)Critical evaluation of the pulsed laser method for single event effects testing and fundamental studies IEEE Trans Nucl Sci 41 2574-2584
  • [9] Buchner S(1994)Two parameter model for predicting SEU rate IEEE Trans Nucl Sci 41 2085-2092
  • [10] McMorrow D(1996)Effects of terrestrial radiation on integrated circuits IEEE Trans Nucl Sci 43 496-504