Determination of clindamycin and its metabolite clindamycin sulfoxide in diverse sewage samples

被引:0
作者
Reinhard Oertel
Sara Schubert
Viktoria Mühlbauer
Bozena Büttner
Conrad Marx
Wilhelm Kirch
机构
[1] Technical University Dresden,Institute of Clinical Pharmacology, Medical Faculty Carl Gustav Carus
[2] Pharmacy of University Hospital Carl Gustav Carus,Institute of Urban Water Management
[3] Technical University Dresden,undefined
来源
Environmental Science and Pollution Research | 2014年 / 21卷
关键词
Clindamycin; Metabolite; Clindamycin sulfoxide; Sewage; LC-MS/MS; Antibiotics;
D O I
暂无
中图分类号
学科分类号
摘要
In a research project on risk management of harmful substances in water cycles, clindamycin and 12 further antibiotics were determined in different sewage samples. In contrast to other antibiotics, an increase of the clindamycin concentration in the final effluent in comparison to the influent of the sewage treatment plant (STP) was observed. A back transformation from the main metabolite clindamycin sulfoxide to clindamycin during the denitrification process has been discussed. Therefore, the concentration of this metabolite was measured additionally. Clindamycin sulfoxide was stable in the STP and the assumption of back transformation of the metabolite to clindamycin was confuted. To explain the increasing clindamycin concentration in the STP, the ratio of clindamycin sulfoxide to clindamycin was observed. The ratio increased in dry spells with concentrated samples and with long dwell time in the sewer system. A short hydraulic retention in waste water system and diluted samples in periods of extreme rainfall lead to a lower ratio of clindamycin sulfoxide to clindamycin concentration. A plausible explanation of this behavior could be that clindamycin was adsorbed strongly to a component of the sewage during this long residence time and in the STP, clindamycin was released. In the common sample preparation in the lab, clindamycin was not released. Measurements of clindamycin and clindamycin sulfoxide in the influent and effluent of STP is advised for sewage monitoring.
引用
收藏
页码:11764 / 11769
页数:5
相关论文
共 30 条
[1]  
Batt AL(2006)Evaluating the vulnerability of surface waters to antibiotic contamination from varying wastewater treatment plant discharges Environ Pollut 142 295-302
[2]  
Bruce IB(2012)Hospital wastewater treatment by membrane bioreactor: performance and efficiency for organic micropollutant elimination Environ Sci Technol 46 1536-1545
[3]  
Aga DS(2009)The presence of pharmaceuticals in the environment due to human use—present knowledge and future challenges J Environ Manage 90 2354-2366
[4]  
Kovalova L(2009)Antibiotics in the aquatic environment—a review—part I Chemosphere 75 417-434
[5]  
Siegrist H(2009)Determination of pharmaceutical compounds in hospital effluents and their contribution to wastewater treatment works Environ Int 35 766-770
[6]  
Singer H(2008)Pharmaceutical compounds in the wastewater process stream in Northwest Ohio Sci Total Environ 397 148-157
[7]  
Wittmer A(2007)Efficiency of conventional drinking-water-treatment processes in removal of pharmaceuticals and other organic compounds Sci Total Environ 377 255-272
[8]  
McArdell CS(2012)Hospital effluent: investigation of the concentrations and distribution of pharmaceuticals and environmental risk assessment Sci Total Environ 430 109-118
[9]  
Kummerer K(2003)In vitro metabolism of clindamycin in human liver and intestinal microsomes Drug Metab Dispos 31 878-887
[10]  
Kummerer K(undefined)undefined undefined undefined undefined-undefined