Heat transfer in a large-scale circulating fluidized bed boiler

被引:10
作者
Cheng L. [1 ]
Wang Q. [1 ]
Shi Z. [1 ]
Luo Z. [1 ]
Ni M. [1 ]
Cen K. [1 ]
机构
[1] Institute for Thermal Power Engineering, State Key Laboratory of Clean Energy Utilization, Zhejiang University
来源
Frontiers of Energy and Power Engineering in China | 2007年 / 1卷 / 4期
关键词
Boiler; Circulating fluidized bed (CFB); Engineering heat transfer; Heat transfer; Industrial boiler;
D O I
10.1007/s11708-007-0071-5
中图分类号
学科分类号
摘要
Heat transfer of a furnace in a large-scale circulating fluidized bed (CFB) boiler was studied based on the analysis of available heat transfer coefficient data from typical industrial CFB boilers and measured data from a 12 MW e, a 50 MWe and a 135 MWe CFB boiler. The heat transfer of heat exchanger surfaces in a furnace, in a steam/water cooled cyclone, in an external heat exchanger and in the backpass was also reviewed. Empirical correlation of heat transfer coefficient was suggested after calculating the two key parameters, solids suspension density and furnace temperature. The correlation approach agrees well with the data from the large-scale CFB boilers. © 2007 Higher Education Press and Springer-Verlag.
引用
收藏
页码:477 / 482
页数:5
相关论文
共 14 条
[11]  
Lin X., Lu J., Liu Q., Et al., Heat transfer measurement and analysis on a suspended heat exchanger in a circulating fluidized bed, Thermal Power Generation, 33, pp. 23-25, (2004)
[12]  
Gupta A.V.S.S.K.S., Nag P.K., Prediction of heat transfer in the cyclone separator of a CFB, Inter J Energy Res, 24, (2000)
[13]  
Wang Q.H., Luo Z.Y., Fang M.X., Et al., Development of a new external heat exchanger for a circulating fluidized bed boiler, Chemical Engineering and Processing, 42, pp. 327-335, (2003)
[14]  
Golriz M.R., Grace J.R., Predicting heat transfer in large-scale CFB boilers, Circulating Fluidized Bed Technology VII, pp. 121-128, (2002)