A PDMS-based microneedle array electrode for long-term ECG recording

被引:0
作者
Renxin Wang
Jianxin Bai
Xiaohang Zhu
Zhaodong Li
Lixia Cheng
Guojun Zhang
Wendong Zhang
机构
[1] North University of China,State Key Laboratory of Dynamic Testing Technology
[2] Science and Technology On Sonar Laboratory,undefined
来源
Biomedical Microdevices | 2022年 / 24卷
关键词
Microneedle array; Flexible dry electrode; PDMS; ECG; Electrode–skin interface impedance;
D O I
暂无
中图分类号
学科分类号
摘要
To acquire high-quality electrocardiogram (ECG) signals, traditional Ag/AgCl wet electrodes used together with conductive gel can effectively reduce electrode–skin interface impedance (EII) in a short term. However, their weaknesses of poor flexibility and instability can no longer meet the long-term monitoring requirements of intelligent wearable devices. Owing to the flexible dry electrode without conductive gel, it is a good choice to solve the critical problem on drying-out of conductive gel. Therefore, we develop a flexible microneedle array electrode (FMAE) based on polydimethylsiloxane (PDMS) substrate, which obtains reliable bioelectrical signals by way of penetrating into the stratum corneum (SC) of the skin. The fabrication process, including silicon mold, twice PDMS shape-transferring and encapsulation, has advantages of low cost, repeatable production and good biocompatibility. Afterwards, by comparing the performance with different electrodes, impedance test results indicate that the impedance of FMAE are smaller and more stable, and ECG tests in long term and at resting/jogging states also verify that FMAE can obtain durable, stable and reliable signals. In conclusion, FMAE is promising in long-term ECG monitoring.
引用
收藏
相关论文
共 57 条
[1]  
Dong W(2019)Stretchable bio-potential electrode with self-similar serpentine structure for continuous, long-term, stable ECG recordings Biomed. Microdevice 21 6-16
[2]  
Cheng X(2001)Micromachined electrodes for biopotential measurements J. Microelectromech. S. 10 10-283
[3]  
Xiong T(2003)A numerical-experimental method to characterize the non-linear mechanical behaviour of human skin Skin Res. Technol. 9 274-266
[4]  
Wang X(2006)The relative contributions of different skin layers to the mechanical behavior of human skin in vivo using suction experiments Med. Eng. Phys. 28 259-1248
[5]  
Griss P(2019)Cohesive dry ECG sensor using silver nanowires and PDMS tuned for adhesion Med Devices Sens. 2 1241-265
[6]  
Enoksson P(2015)A flexible dry micro-dome electrode for ECG monitoring Microsyst. Technol. 21 255-470
[7]  
Tolvanen-Laakso HK(2016)A baseline wander tracking system for artifact rejection in long-term electrocardiography IEEE Trans. Biomed. Circuits Syst. 10 463-587
[8]  
Hendriks FM(2017)“Skin-potential variation insensitive dry electrodes for ECG recording”, Bio.-Med. Eng. 64 581-142
[9]  
Brokken D(2004)Microneedles for transdermal drug delivery Adv. Drug Deliver. Rev. 56 141-2904
[10]  
van Eemeren JTWM(2002)Instant neural control of a movement signal Nature 416 2898-998