Ambulatory monitoring

被引:6
作者
Brown K. [1 ,2 ]
Hilton P. [1 ]
机构
[1] Department of Gynaecology, Royal Victoria Infirmary, Newcastle upon Tyne
[2] Department of Gynaecology, Royal Victoria Infirmary, Newcastle upon Tyne
关键词
Ambulatory urodynamics; Cystometry; Detrusor instability; Incontinence;
D O I
10.1007/BF02765598
中图分类号
学科分类号
摘要
Ambulatory monitoring has been hailed as the 'way forward' in urodynamic investigation. Its introduction has caused much excitement and there is no doubt that it detects more abnormalities than does conventional cystometry. It is, however, labour intensive and time consuming for both operator and patient, and requires commitment from both to be successful. No standards have been set as to how long a test ought to last, how many voids are required and how to interpret traces. To date the standard cystometric criteria of normality have been applied, but this would appear to be inappropriate. Several commercial companies have developed systems and are marketing them widely as an adjunct, or alternative, to conventional cystometry. It is recommended that before this technique is introduced into routine clinical practice it is fully evaluated, with standardization of terminology relating to its use.
引用
收藏
页码:369 / 376
页数:7
相关论文
共 44 条
  • [21] Styles R.A., Neal D.E., Griffiths C.J., Ramsden P.D., Long term monitoring of bladder pressure in chronic retention of urine: The relationship between detrusor activity and upper tract dilatation, J Urol, 140, pp. 330-334, (1988)
  • [22] Van Waalwijk Van Doom E.S.C., Remmers A., Janknegt R.A., Conventional and extramural ambulatory urodynamic testing of the lower urinary tract in female volunteers, J Urol, 147, pp. 1319-1326, (1992)
  • [23] Heslington K., Hilton P., A comparison of ambulatory monitoring and conventional cystometry in asymptomatic female volunteers, Neurourol Urodyn, 14, pp. 534-535, (1995)
  • [24] Webb R.J., Styles R.A., Griffiths C.J., Ramsden P.D., Neal D.E., Ambulatory monitoring of bladder pressure in patients with low compliance as a result of neurogenic bladder dysfunction, Br J Urol, 64, pp. 150-154, (1989)
  • [25] McInerney P.D., Vanner T.F., Sab H., Stephenson T.P., Ambulatory urodynamics, Br J Urol, 67, pp. 272-274, (1991)
  • [26] Heslington K., Hilton P., The incidence of detrusor instability by ambulatory monitoring in symptomatic females with normal conventional cystometry, Proceedings of Twenty Fifth Annual Meeting of the International Contience Society, pp. 415-416, (1995)
  • [27] Turner-Warwick R.T., Some clinical aspects of detrusor dysfunction, J Urol, 113, pp. 539-544, (1975)
  • [28] Wijkstra H., Van Kerrebroeck Ph.E.V.A., Koldewijn E., Debruyne F.M.J., The use of heat sensors in detecting urine leakage during long term urodynamics, Neurourol Urodyn, 10, pp. 422-423, (1991)
  • [29] Eckford S.D., Abrams P.H., A new temperature device to detect incontinent episodes during ambulatory monitoring, Neurourol Urodyn, 11, pp. 448-450, (1992)
  • [30] Webb R.J., Griffiths C.J., Ramsden P.D., Neal D.E., Measurement of voiding pressures on ambulatory monitoring: Comparison with conventional cystometry, Br J Urol, 65, pp. 152-154, (1990)