Ambulatory monitoring

被引:6
作者
Brown K. [1 ,2 ]
Hilton P. [1 ]
机构
[1] Department of Gynaecology, Royal Victoria Infirmary, Newcastle upon Tyne
[2] Department of Gynaecology, Royal Victoria Infirmary, Newcastle upon Tyne
关键词
Ambulatory urodynamics; Cystometry; Detrusor instability; Incontinence;
D O I
10.1007/BF02765598
中图分类号
学科分类号
摘要
Ambulatory monitoring has been hailed as the 'way forward' in urodynamic investigation. Its introduction has caused much excitement and there is no doubt that it detects more abnormalities than does conventional cystometry. It is, however, labour intensive and time consuming for both operator and patient, and requires commitment from both to be successful. No standards have been set as to how long a test ought to last, how many voids are required and how to interpret traces. To date the standard cystometric criteria of normality have been applied, but this would appear to be inappropriate. Several commercial companies have developed systems and are marketing them widely as an adjunct, or alternative, to conventional cystometry. It is recommended that before this technique is introduced into routine clinical practice it is fully evaluated, with standardization of terminology relating to its use.
引用
收藏
页码:369 / 376
页数:7
相关论文
共 44 条
  • [1] Mackay R.S., Radiotelemetering from within the human body, IRE Trans Med Electronics ME-6, 11, pp. 100-105, (1959)
  • [2] Gleason D.M., Lattimer J.K., Bauxbaum C., Bladder pressure telemetry, J Urol, 94, pp. 252-256, (1965)
  • [3] Warrell D.W., Watson B.W., Shelley T., Intravesical pressure measurement in women during movement using a radio-pill and an air-probe, J Obstet Gynaecol Br Commonw, 70, (1963)
  • [4] Thuroff J.W., Jonas U., Frohneberg E.P., Hohenfellner R., Telemetric urodynamic investigations in normal males, Urol Int, 35, pp. 427-434, (1980)
  • [5] James E.D., The behavior of the bladder during physical activity, J Urol, 50, pp. 387-394, (1978)
  • [6] Kvarnstein B., Aase O., Hansen T.-E., Dobloug P., A new method with fibreoptic transducers used for simultaneous recording of intravesical and urethral pressure during physiological filling and voiding phases, J Urol, 130, pp. 504-506, (1983)
  • [7] Ask P., Hok B., Pressure measurement techniques in urodynamic investigations, Neurourol Urodyn, 9, pp. 1-15, (1990)
  • [8] Bhatia N.N., Bradley W.E., Haldeman S., Johnson B.K., Continuous montoring of bladder and urethral pressures: New technique, Urology, 18, pp. 207-210, (1981)
  • [9] Bhatia N.N., Bradley W.E., Haldeman S., Johnson B.K., Continuous urodynamic monitoring, Urology, 18, pp. 39-41, (1981)
  • [10] Van Waalwijk Van Doom E.S.C., Aap V., Ijsenbrandt H., Kimmich H.P., Debruyne F.M.J., A miniature eight channel PCM telemetry system for objectivation of occult unstable bladder and sphincter disorders, Proceedings of the Fourteenth Annual Meeting of the International Continence Society., pp. 168-170, (1984)