Detectability of Subsurface Defects with Different Width-to-Depth Ratios in Concrete Structures Using Pulsed Thermography

被引:0
作者
Quang Huy Tran
Jungwon Huh
Choonghyun Kang
Bang Yeon Lee
In-Tae Kim
Jin-Hee Ahn
机构
[1] Chonnam National University,Department of Civil and Environmental Engineering
[2] Chonnam National University,School of Architecture
[3] Pusan National University,Department of Civil Engineering
[4] Gyeongnam National University of Science and Technology,Department of Civil Engineering
来源
Journal of Nondestructive Evaluation | 2018年 / 37卷
关键词
Concrete deterioration; Subsurface delamination; Pulsed thermography; Width-to-depth (w2d) ratio; Nondestructive testing; pulsed phase thermography;
D O I
暂无
中图分类号
学科分类号
摘要
The active thermography technique is one of the most effective nondestructive tests for evaluating subsurface delaminations in concrete structures. The limitation of this method, which has been studied for some time, is that the width of the smallest detectable defect should be at least two times larger than its depth. However, controversy on this matter remains for concrete material with largely uncertain homogeneity, although the development of the infrared (IR) detector technology improved the above-mentioned limitation. In this study, the pulsed thermography (PT) technique is therefore conducted in the laboratory to investigate the detectability of delaminations with the width-to-depth ratio (w2d) ranging from 1.0 to 7.9 by using a long IR wavelength detector with a focal plane array of 640 ×\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\times $$\end{document} 480 pixels. The study focuses on the w2d ratio lower than 2.0. A concrete specimen was made with 12 embedded simulated delaminations having different sizes and depths. The results showed that a combination of PT and pulsed phase thermography can be used to detect delaminations with a w2d ratio equal or greater than 1.25. In addition, the absolute contrast above the delamination increases with the higher w2d ratio, indicating that even for a relatively deep delamination, it is still detectable if a delamination is provided by appropriate heat energy and its size is sufficiently large. Finally, the study also indicates that as the amount of heating energy provided is increased, the greater accuracy in predicting the depth can be obtained.
引用
收藏
相关论文
共 37 条
[1]  
Tran QH(2017)Effects of ambient temperature and relative humidity on subsurface defect detection in concrete structures by active thermal imaging Sensors 17 1718-582
[2]  
Han D(2017)The methodology for defect quantification in concrete using IR thermography J. Civ. Eng. Manag. 23 573-263
[3]  
Kang C(2003)Detection of shallow voids in concrete structures with impulse thermography and radar NDT&E Int. 36 257-109
[4]  
Haldar A(2013)Nondestructive testing with thermography Eur. J. Phys. 34 91-143
[5]  
Huh J(2016)Thermal NDT Research at Tomsk Polytechnic University Quant. InfraRed Thermogr. 13 128-92
[6]  
Milovanovic B(2008)Defect detection of concrete structures using both infrared thermography and elastic waves Autom. Constr. 18 87-93
[7]  
Pecur IB(2015)Determination of the applicability and limits of void and delamination detection in concrete structures using infrared thermography NDT&E Int. 74 87-43
[8]  
Stirmer N(2016)Non-destructive testing with transient thermography on composite materials R & D J. S. Afr. Inst. Mech. Eng. 32 35-849
[9]  
Maierhofer Ch(2005)Investigation of concrete structures with pulse phase thermography RILEM Mater. Struct. 38 843-55
[10]  
Brink A(2018)Quantitative evaluation of active thermography using contrast-to-noise ratio Appl. Opt. 57 49-undefined