Multidetector CT in children: current concepts and dose reduction strategies

被引:0
作者
Rutger A. J. Nievelstein
Ingrid M. van Dam
Aart J. van der Molen
机构
[1] University Medical Centre Utrecht,Department of Pediatric Radiology, Wilhelmina Children’s Hospital
[2] Leiden University Medical Centre,Department of Radiology, C
来源
Pediatric Radiology | 2010年 / 40卷
关键词
Multidetector CT; Technique; Justification; Optimisation; Child;
D O I
暂无
中图分类号
学科分类号
摘要
The recent technical development of multidetector CT (MDCT) has contributed to a substantial increase in its diagnostic applications and accuracy in children. A major drawback of MDCT is the use of ionising radiation with the risk of inducing secondary cancer. Therefore, justification and optimisation of paediatric MDCT is of great importance in order to minimise these risks (“as low as reasonably achievable” principle). This review will focus on all technical and non-technical aspects relevant for paediatric MDCT optimisation and includes guidelines for radiation dose level-based CT protocols.
引用
收藏
页码:1324 / 1344
页数:20
相关论文
共 50 条
  • [1] Multidetector CT in children: current concepts and dose reduction strategies
    Nievelstein, Rutger A. J.
    van Dam, Ingrid M.
    van der Molen, Aart J.
    PEDIATRIC RADIOLOGY, 2010, 40 (08) : 1324 - 1344
  • [2] CT radiation dose and radiation reduction strategies
    Park, Michael Yong
    Jung, Seung Eun
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2011, 54 (12): : 1262 - 1268
  • [3] Dose reduction in multidetector CT of the urinary tract. Studies in a phantom model
    Coppenrath, E.
    Meindl, T.
    Herzog, P.
    Khalil, R.
    Mueller-Lisse, U.
    Krenn, L.
    Reiser, M.
    Mueller-Lisse, U. G.
    EUROPEAN RADIOLOGY, 2006, 16 (09) : 1982 - 1989
  • [4] Dose reduction in multidetector CT of the urinary tract. Studies in a phantom model
    E. Coppenrath
    T. Meindl
    P. Herzog
    R. Khalil
    U. Mueller-Lisse
    L. Krenn
    M. Reiser
    U. G. Mueller-Lisse
    European Radiology, 2006, 16 : 1982 - 1989
  • [5] Optimised low-dose multidetector CT protocol for children with cranial deformity
    Jose Luis Vazquez
    Miguel Angel Pombar
    Jose Manuel Pumar
    Victor Miguel del Campo
    European Radiology, 2013, 23 : 2279 - 2287
  • [6] Multidetector CT Dose: Clinical Practice Improvement Strategies From a Successful Optimization Program
    Wallace, Anthony B.
    Goergen, Stacy K.
    Schick, Daniel
    Soblusky, Tina
    Jolley, Damien
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2010, 7 (08) : 614 - 624
  • [7] Optimised low-dose multidetector CT protocol for children with cranial deformity
    Luis Vazquez, Jose
    Angel Pombar, Miguel
    Manuel Pumar, Jose
    Miguel del Campo, Victor
    EUROPEAN RADIOLOGY, 2013, 23 (08) : 2279 - 2287
  • [8] Medical radiation exposure in children and dose reduction
    Jung, Ah Young
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2011, 54 (12): : 1277 - 1283
  • [9] An overview of exposure parameters, dose measurements and strategies for dose reduction in pediatric CT examinations
    Akhlaghi, P.
    Hakimabad, H. Miri
    Motavalli, L. Rafat
    RADIOPROTECTION, 2014, 49 (01) : 9 - 15
  • [10] First experiences with multidetector CT in traumatized children
    Hörmann, M
    Scharitzer, M
    Philipp, M
    Metz, VM
    Lomoschitz, F
    EUROPEAN JOURNAL OF RADIOLOGY, 2003, 48 (01) : 125 - 132