Multiple regression models for energy consumption of office buildings in different climates in China

被引:13
作者
Zhou S. [1 ]
Zhu N. [1 ]
机构
[1] School of Environmental Science and Engineering, Tianjin University, Tianjin
关键词
building envelope; different climates; energy consumption; office building; regression model;
D O I
10.1007/s11708-012-0220-z
中图分类号
学科分类号
摘要
The energy consumption of office buildings in China has been growing significantly in recent years. Obviously, there are significant relationships between building envelope and the energy consumption of office buildings. The 8 key building envelope influencing factors were found in this paper to evaluate their effects on the energy consumption of the air-conditioning system. The typical combinations of the key influencing factors were performed in Trnsy simulation. Then on the basis of the simulated results, the multiple regression models were developed respectively for the four climates of China-hot summer and warm winter, hot summer and cold winter, cold, and severely cold. According to the analysis of regression coefficients, the appropriate building envelope design schemes were discussed in different climates. At last, the regression model evaluations consisting of the simulation evaluations and the actual case evaluations were performed to verify the feasibility and accuracy of the regression models. The error rates are within ±5% in the simulation evaluations and within ±15% in the actual case evaluations. It is believed that the regression models developed in this paper can be used to estimate the energy consumption of office buildings in different climates when various building envelope designs are considered. © 2012 Higher Education Press and Springer-Verlag Berlin Heidelberg.
引用
收藏
页码:103 / 110
页数:7
相关论文
共 25 条
  • [1] Cai, W.G., Wu, Y., Zhong, Y., Ren, H., China building energy consumption: Situation, challenges and corresponding measures (2009) Energy Policy, 37 (6), pp. 2054-2059
  • [2] Jiang, Y., Wu, X., (2010) 2010 Annual Report on China Building Energy Efficiency, , Beijing: China Architecture & Building Press
  • [3] Kong, X.F., Lu, S.L., Wu, Y., A review of building energy efficiency in China during "Eleventh Five-year Plan" period (2012) Energy Policy, 41, pp. 624-635
  • [4] Jie, P.F., Tian, Z., Yuan, S.S., Modeling the dynamic characteristics of a district heating network (2012) Energy, 39, pp. 126-134
  • [5] Chang, C.C., Zhao, J., Zhu, N., Energy saving effect prediction and post evaluation of air-conditioning system in public buildings (2011) Energy and Building, 43 (11), pp. 3243-3249
  • [6] Zhao, J., Xin, Y.J., Tong, D.D., Energy consumption quota of public buildings based on statistical analysis (2012) Energy Policy, 43, pp. 362-370
  • [7] Jie, P.F., Li, D.Y., Zhu, N., Optimization of regulation methods in district heating systems (2012) Advanced Materials Research, 490, pp. 1475-1480
  • [8] Xie, Z.G., Hong, H.B., Li, S.Y., Interference effects of high-rise buildings: Effects of building shapes and correlations of envelope interference factors (2008) Journal of Building Structures, 29 (1), pp. 13-18
  • [9] Carlo, J., Lamberts, R., Development of envelope efficiency labels for commercial buildings: Effect of different variables on electricity consumption (2008) Energy and Building, 40 (11), pp. 2002-2008