Stenting of Ductus Arteriosus in a Neonate with Truncus Arteriosus and Interrupted Aortic Arch Associated with a Right Aortic Arch

被引:0
作者
Miho Sakata
Yasunobu Hayabuchi
Miki Inoue
Shoji Kagami
机构
[1] School of Medicine University of Tokushima,Department of Pediatrics
来源
Pediatric Cardiology | 2009年 / 30卷
关键词
Ductus arteriosus; Interrupted aortic arch; Truncus arteriosus;
D O I
暂无
中图分类号
学科分类号
摘要
This report describes a case in which successful stenting of ductus arteriosus (DA) was performed for a 27-day-old boy with truncus arteriosus (TA) and interrupted aortic arch (IAA). The patent DA was associated with a right aortic arch. During the balloon catheter crossing of the ductus, the DA and descending aorta shifted toward the left side, making appropriate stent placement difficult. Additionally, the DA was longer than in previously reported cases with left aortic arch, thus requiring a longer stent. This experience suggests that DA stenting in neonates with TA and IAA averts surgical repair during the early neonatal period.
引用
收藏
页码:1180 / 1183
页数:3
相关论文
共 65 条
  • [1] Alwi M(2004)Initial results and medium-term follow-up of stent implantation of patent ductus arteriosus in duct-dependent pulmonary circulation J Am Coll Cardiol 44 438-445
  • [2] Choo KK(2005)Ductal anatomy: a determinant of successful stenting in hypoplastic left heart syndrome Pediatr Cardiol 26 200-205
  • [3] Latiff HA(2006)Initial transcatheter palliation of hypoplastic left heart syndrome Catheter Cardiovasc Interv 68 719-726
  • [4] Kandavello G(2004)Stenting the neonatal arterial duct in duct-dependent pulmonary circulation: new techniques, better results J Am Coll Cardiol 43 107-112
  • [5] Samion H(2007)Neonatal rhabdomyoma causing right ventricular inflow obstruction with duct-dependent pulmonary blood flow: successful stenting of PDA Catheter Cardiovasc Interv 69 881-885
  • [6] Mulyadi MD(2006)Truncus arteriosus associated with interrupted aortic arch in 50 neonates: a congenital heart surgeons society study Ann Thorac Surg 81 214-223
  • [7] Boucek MM(2003)Stenting of the ductus arteriosus and banding of the pulmonary arteries: basis for various surgical strategies in newborns with multiple left heart obstructive lesions Heart 89 645-650
  • [8] Mashburn C(2004)Stent implantation in the ductus arteriosus for pulmonary blood supply in congenital heart disease Catheter Cardiovasc Interv 61 242-252
  • [9] Kunz E(2005)Repair of truncus arteriosus and aortic arch interruption: outcome analysis Ann Thorac Surg 79 2077-2082
  • [10] Chan KC(1998)Stent implantation of the arterial duct in newborns with duct-dependent circulation Eur Heart J 19 1401-1409