A study on mechanical behavior and wear performance of a metal–metal Co–30Cr biomedical alloy with different molybdenum addition and optimized using Taguchi experimental design

被引:0
作者
Amit Aherwar
Amit Singh
Amar Patnaik
机构
[1] Madhav Institute of Technology and Science,Mechanical Engineering Department
[2] Malaviya National Institute of Technology,Mechanical Engineering Department
来源
Journal of the Brazilian Society of Mechanical Sciences and Engineering | 2018年 / 40卷
关键词
Molybdenum; Mechanical; Sliding wear; Design of experiment; FESEM/EDAX;
D O I
暂无
中图分类号
学科分类号
摘要
Molybdenum-added biomedical alloy has been prepared using a high-temperature vertical vacuum casting technique with five (0, 1, 2, 3, and 4 wt%) diverse weight percentages. The density, microhardness, and sliding wear behavior of the fabricated alloys were studied, showing that the addition of molybdenum content in the metal–metal alloy (i.e., Co–30Cr) increases the density from 7.2 to 8.7 g/cc for 0–4 wt% of Mo, respectively. Similarly, the hardness of prepared biomedical alloy also increases from 653 to 720 HV on addition of 0–4 wt% Mo particulate, respectively. The hardness is investigated by the microhardness tester. The aim of this current research work is to optimized the sliding wear behavior of molybdenum-added Co–30Cr alloy for implant material by Taguchi experimental design technique at five different normal loads (5–25 N), sliding velocities (0.26–1.3 m/s), sliding distance (500–2500 m), and reinforcement, i.e., Mo (0–4 wt%) respectively. To obtain the optimum wear response of prepared biomedical alloy added with Mo contents, the Taguchi L25 orthogonal array was implemented. The wear test is performed on a pin-on-disc tribometer against a hardened alloy steel (EN-31) disc under different operating conditions at room temperature. Afterwards, field-emission scanning electron microscopy and atomic force microscopy were utilized to analyze the microstructure, contour of wear mechanism, and 3D surface topography of samples after test run.
引用
收藏
相关论文
共 132 条
[1]  
Aherwar A(2016)Cobalt based alloy: a better choice biomaterial for hip implants Trends Biomater Artif Organs 30 50-55
[2]  
Singh A(2017)Preliminary evaluations on development of new materials for hip joint femoral head J Mater Des Appl 3 1-22
[3]  
Patnaik A(2016)Current and future biocompatibility aspects of biomaterials for hip prosthesis J Bioeng 115 592-600
[4]  
Aherwar A(2016)Characterization of the interface between cast-to Co–Cr implant cylinders and cast Co–Cr alloys J Prosthet Dentist 206 233-238
[5]  
Patnaik A(2011)Powder metallurgical processing of Co–28% Cr–6% Mo for dental implants: physical, mechanical and electrochemical properties Powder Technol 12 193-206
[6]  
Bahraminasab M(2006)Mechanical properties of metals for biomedical applications using powder metallurgy process: a review Met Mater Int 60 139-147
[7]  
Singh A(2015)Defects-tolerant Co–Cr–Mo dental alloys prepared by selective laser melting Dent Mater 56 687-711
[8]  
Aherwar A(2016)Fabrication, tribological and corrosion behaviors of ultra-fine grained Co–28 Cr–6 Mo alloy for biomedical applications J Mech Behav Biomed Mater 33 5487-5503
[9]  
Singh A(2007)The design and manufacture of biomedical surfaces CIRP Ann Manuf Technol 55 473-480
[10]  
Patnaik A(2012)Fretting corrosion of CoCrMo and Ti6Al4V interfaces Biomaterials 55 677-684