Employing a femtosecond laser as an initial step in cataract surgery has the clear potential to provide more precise capsulotomies and full lens fragmentation in cases of pre-existing astigmatism in conjunction with relaxing corneal incisions. In the long run femtosecond laser-assisted cataract surgery might replace phacoemulsification which has been the standard in cataract surgery over the last 20 years. Besides precision and predictability, the low rate of complications impresses surgeons working with the technology, particularly those employing a laser with a fluid-filled interface which seems to prevent major complications including increases in intraocular pressure. © 2014 Springer-Verlag Berlin Heidelberg.
引用
收藏
页码:614 / 623
页数:9
相关论文
共 36 条
[1]  
Krasnov M.M., Laser-phakopuncture in the treatment of soft cataracts, Br J Ophthalmol, 59, pp. 96-98, (1975)
[2]  
Ratkay-Traub I., Juhasz T., Horvath C., Et al., Ultra-short pulse (femtosecond) laser surgery: Initial use in LASIK flap creation, Ophthalmol Clin North Am, 14, pp. 347-355, (2001)
[3]  
Keates R.H., Steinert R.F., Puliafito C.A., Maxwell S.K., Long-term follow-up of Nd: YAG laser posterior capsulotomy, J Am Intraocul Implant Soc, 10, pp. 164-168, (1984)
[4]  
Nagy Z., Takacs A., Filkorn T., Sarayba M., Initial clinical evaluation of an intraocular femtosecond laser in cataract surgery, J Refract Surg, 25, pp. 1053-1060, (2009)
[5]  
Schultz T., Conrad-Hengerer I., Hengerer F.H., Dick H.B., Intraocular pressure variation during femtosecond laser-assisted cataract surgery using a fluid-filled interface, J Cataract Refract Surg, 39, pp. 22-27, (2013)
[6]  
Dick H.B., Gerste R.D., Rivera R.P., Schultz T., Femtosecond laser-assisted cataract surgery without ophthalmic viscosurgical devices, J Refract Surg, 29, pp. 784-787, (2013)
[7]  
Friedman N.J., Palanker D.V., Schuele G., Et al., Femtosecond laser capsulotomy, J Cataract Refract Surg, 37, pp. 1189-1198, (2011)
[8]  
Dick H.B., Gerste R.D., Schultz T., Waring 3rd G.O., Capsulotomy or capsulorhexis in femtosecond laser-assisted cataract surgery?, J Cataract Refract Surg, 39, (2013)
[9]  
Auffarth G.U., Reddy K.P., Ritter R., Et al., Comparison of the maximum applicable stretch force after femtosecond laser-assisted and manual anterior capsulotomy, J Cataract Refract Surg, 39, pp. 105-109, (2013)
[10]  
Dick H.B., Schultz T., Femtosecond laser-assisted cataract surgery in infants, J Cataract Refract Surg, 39, pp. 665-668, (2013)