Preparation, characterization and performance studies of polyethersulfone (PES) - pyrolytic carbon (PyC) composite membranes

被引:0
作者
Reza Peighami
Mohamadreza Mehrnia
Fatemeh Yazdian
Mozhgan Sheikhpour
Hamid Esmaeili
机构
[1] University of Tehran,Department of Life Science Engineering, Faculty of New Science and Technology
[2] University of Tehran,School of Chemical Engineering, College of Engineering
[3] University of Tehran,Department of Microbial Biotechnology, School of Biology, Faculty of Science
[4] Petroleum University of Technology,School of Chemical Engineering
来源
Journal of Polymer Research | 2017年 / 24卷
关键词
Polyethersulphone (PES); Pyrolitic carbon (PyC); SEM; AFM; Contact angle measurements; Insulin diffusivity;
D O I
暂无
中图分类号
学科分类号
摘要
Polyethersulfone (PES) is one of the most common polymers used to manufacture membranes. This work focuses on introducing and developing a novel polymer-based membrane applicable in the bio-artificial pancreas. The novel membrane based on the mixture of PES and Pyrolytic carbon (PyC) was studied and compared to PES as a reference. The PES/PyC blend membranes were characterized by top surface SEM, cross section SEM, AFM, contact angle pure water flux, insulin rejection, rejection of immune cells and molecules, and insulin diffusivity performance. In addition, the porosity of the membranes, mean pore size and mean pore density were also measured. The AFM and SEM images indicate that addition of synthesized PyC in the casting solution results in a membrane with high surface and sub-layer porosity and the addition 0.1 wt.% PyC to the casting solution reduced the surface roughness from 22.4 nm to 4.8 nm. The contact angle measurements reveal that the hydrophobicity of pure PES membrane enhanced with increasing the PyC concentration in the casting solution. With the increase of PyC from 0.0 wt.% to 0.1 wt.% in the casting solution, pure water flux reduces from 184 to 153 (L/m2h), insulin rejection reduces from 12 to 9.3%, rejection of immune cells and molecules reduce from 91.8 to 83% and insulin diffusivity increased from1.22E-8 to 1.46E-8. Furthermore, the resulting numbers for the mean pore size, mean pore density, and porosity of the PES-PyC(0.1 wt.%) membrane indicate a considerable improvement compared to pure PES membrane with increasing from 5.5 nm to 7 nm, 26 to 43 pores/area (area stand for the size of membrane surface in which pores were counted), and 68.3% to 84.6%, respectively. At the end, the statistical analysis was performed.
引用
收藏
相关论文
共 114 条
[1]  
Moriya A(2009)Preparation of poly(lactic acid) hollow fiber membranes via phase separation methods J Membr Sci 342 307-312
[2]  
Maruyama T(1984)Islet immune-isolation; the use of hybrid artificial organs to prevent islet tissue rejection World J Surg 8 221-257
[3]  
Ohmukai Y(2006)Effect of rat-to-mouse bioartificial pancreas xenotransplantation on diabetic renal damage and survival Pancreas 32 249-5892
[4]  
Sotani T(2004)PVA hydrogel sheet macroencapsulation for the bioartificial pancreas Biomaterials 25 5885-534
[5]  
Matsuyama H(2012)Immunoisolation effect of polyvinyl alcohol (PVA) macroencapsulated islets in type 1 diabetes therapy Cell Transplant 21 525-378
[6]  
Scharp DW(1990)Theoretical and experimental analysis of a hybrid bioartificial membrane pancreas: a distributed parameter model taking into account starling fluxes J Membr Sci 52 351-47
[7]  
Mason NS(2008)Preparation, characterization and performance studies of polysulfone membranes using PVP as an additive J Membr Sci 315 36-183
[8]  
Sparks RE(1999)Membrane formation mechanism based on precipitation kinetics and membrane morphology: flat and hollow fiber polysulfone membranes J Membr Sci 155 171-371
[9]  
Sakata N(1996)Recent advances in the formation of phase inversion membranes made from amorphous or semi-crystalline polymers J Membr Sci 113 361-57
[10]  
Gu Y(2004)Effect of molecular weight of polymeric additives on formation, permeation properties and hypochlorite treatment of asymmetric polyacrylonitrile membranes J Membr Sci 243 45-185