The aim of this study was to determine the attenuation of gamma and X-rays with different energies caused by passage through different materials. To this end, different materials with a range of atomic numbers were chosen to measure gamma and X-ray attenuation coefficients and to explore the mechanisms of interaction of gamma and X-rays with matter of various kinds. It is shown that the attenuation coefficients first decrease and then increase with increase in the radiation (photon) energy. The attenuation of gamma and X-rays passing through materials with high atomic number is greater than that in materials with low atomic number. The attenuation minimum is related to the atomic number of the irradiated materials. The larger the atomic number is, the lower the energy corresponding to attenuation minimum is. Photoelectric and Compton effects are the main processes when gamma rays pass through individual materials with high and low atomic numbers, respectively. Therefore, for radiotherapy and radiation protection, different methods should be considered and selected for the use of gamma and X-rays of different energies for use in different materials.
引用
收藏
相关论文
共 100 条
  • [1] Bethesda MD(2005)Structural shielding design for medical imaging X-ray facilities Phys. Med. Biol. 50 4243-4244
  • [2] Adhikari KP(2018)A medical physics perspective: radiation therapy in Nepal Med. Phys. Int. J. 6 145-147
  • [3] Rosenblatt E(2018)Planning national radiotherapy services Front. Oncol. 32 2380-2398
  • [4] Lightstone AW(2005)Intracranial stereotactic positioning systems: report of the American Association of Physicists in Medicine Radiation Therapy Committee Task Group No. 68 Med. Phys. 30 175-187
  • [5] Benedict SH(2003)Utilization of ilmenite/epoxy composite for neutrons and gamma rays attenuation Ann. Nucl. Energy 22 125-138
  • [6] Bova FJ(1987)The repair of concrete structures Cem. Concrete Assoc. 55 2376-2384
  • [7] El-Sayed AA(2008)Study on composite material for shielding mixed neutron and IEEE Trans. Nucl. Sci. 63 350-354
  • [8] El-Sarraf MA(2014)-rays Ann. Nucl. Energy 109 S205-S211
  • [9] Gaber FA(2015)Investigation of lead borate glasses doped with aluminum oxide as gamma ray shielding materials Radiat. Saf. J. 4 235-243
  • [10] Allen R(2016)Attenuation of X and gamma rays in personal radiation shielding protective clothing J. Radiosurg. SBRT 94 899-904