Direct electrochemistry of immobilized hemoglobin and sensing of bromate at a glassy carbon electrode modified with graphene and β-cyclodextrin

被引:0
作者
Selvakumar Palanisamy
Yi-Ting Wang
Shen-Ming Chen
Balamurugan Thirumalraj
Bih-Show Lou
机构
[1] National Taipei University of Technology,Department of Chemical Engineering and Biotechnology
[2] Chang Gung University,Chemistry Division, Center for General Education
来源
Microchimica Acta | 2016年 / 183卷
关键词
Heterogeneous electron transfer; Amperometry; Cyclic voltammetry; Nanocomposite; Scanning electron microscopy; FTIR; Biosensor;
D O I
暂无
中图分类号
学科分类号
摘要
We describe the use of a nanocomposite consisting of graphene and β-cyclodextrin (β-CD) which was used to modify a glassy carbon electrode (GCE) to serve as a matrix for immobilization of hemoglobin (Hb). The composite was characterized by scanning electron microscopy, UV-vis and FTIR spectroscopy. The modified electrode displays an enhanced and well-defined quasi reversible peaks for the heme protein at a formal potential of −0.284 V (vs. Ag/AgCl). The direct electrochemistry of Hb is strongly enhanced at this modified electrode compared to electrodes not modified with graphene or β-CD. The heterogeneous electron transfer rate constant (Ks) is 3.18 ± 0.7 s−1 which indicates fast electron transfer. The biosensor exhibits excellent electrocatalytic activity towards the reduction of bromate, with a linear amperometric response in the 0.1 to 176.6 μM concentration range at a working voltage of −0.33 V. The sensitivity is 3.39 μA μM−1 cm−2, and the detection limit is 33 nM. The biosensor is fast, selective, well repeatable and reproducible, and therefore represents a viable platform for sensing bromate in aqueous samples.
引用
收藏
页码:1953 / 1961
页数:8
相关论文
共 170 条
  • [1] Marák J(2012)On-line capillary isotachophoresis–capillary zone electrophoresis analysis of bromate in drinking waters in an automated analyzer with coupled columns and photometric detection J Chromatogr A 1267 252-258
  • [2] Staňová A(2014)Cetyltrimethylammonium-coated magnetic nanoparticles for the extraction of bromate, followed by its spectrophotometric determination Microchim Acta 181 925-933
  • [3] Vaváková V(2012)Automated solid-phase spectrophotometric system for optosensing of bromate in drinking waters Anal Methods 4 1229-1236
  • [4] Hrenáková M(2015)Graphene-modified Pd/C cathode and Pd/GAC particles for enhanced electrocatalytic removal of bromate in a continuous three-dimensional electrochemical reactor Water Res 77 1-12
  • [5] Kaniansky D(2013)A simple yet effective chromogenic reagent for the rapid estimation of bromate and hypochlorite in drinking water Analyst 138 434-437
  • [6] Saraji M(1998)Spectrophotometric determination of low levels of bromate in drinking water after reaction with fuchsin Analyst 123 291-294
  • [7] Khaje N(2005)Chloride interference in the determination of bromate in drinking water by reagent free ion chromatography with mass spectrometry detection J Chromatogr A 1085 42-46
  • [8] Ghani M(2005)Trace analysis of bromate, chlorate, iodate, and perchlorate in natural and bottled waters Environ Sci Technol 39 4586-4593
  • [9] Oliveira SM(2010)Cyclodextrin functionalized graphene nanosheets with high supramolecular recognition capability: synthesis and host − guest inclusion for enhanced electrochemical performance ACS Nano 4 4001-4010
  • [10] Oliveira HM(2012)Synthesis, characterization and performance of polyaniline–polyoxometalates (XM Sensors Actuators B Chem 173 346-353