Applications of minimally invasive cardiac output monitors

被引:6
作者
Porhomayon J. [1 ,3 ]
Zadeii G. [2 ]
Congello S. [2 ]
Nader N.D. [1 ]
机构
[1] Division of Critical Care and Pain Medicine, Department of Anesthesiology, State University of New York at Buffalo School of Medicine and Biomedical Sciences, Buffalo, NY
[2] University of Iowa, Mason City Cardiology, Mason City, IA
[3] VA Medical Center, Buffalo, NY 14215
关键词
Pulmonary Artery Catheter; Pulse Pressure Variation; Stroke Volume Variation; Pulse Contour; Pulse Contour Analysis;
D O I
10.1186/1865-1380-5-18
中图分类号
学科分类号
摘要
Because of the increasing age of the population, critical care and emergency medicine physicians have seen an increased number of critically ill patients over the last decade. Moreover, the trend of hospital closures in the United States t imposes a burden of increased efficiency. Hence, the identification of devices that facilitate accurate but rapid assessments of hemodynamic parameters without the added burden of invasiveness becomes tantamount. The purpose of this review is to understand the applications and limitations of these new technologies. © 2012 Porhomayon et al.
引用
收藏
相关论文
共 61 条
[1]  
Fegler G., Measurement of cardiac output in anaesthetized animals by a thermodilution method, Q J Exp Physiol Cogn Med Sci, 39, 3, pp. 153-164, (1954)
[2]  
Stewart G.N., Researches on the circulation time and on the influences which affect it, J Physiol, 22, 3, pp. 159-183, (1897)
[3]  
Reade M.C., Angus D.C., PAC-Man: Game over for the pulmonary artery catheter?, Crit Care, 10, 1, (2006)
[4]  
Ivanov R., Allen J., Calvin J.E., The incidence of major morbidity in critically ill patients managed with pulmonary artery catheters: A meta-analysis, Critical Care Medicine, 28, 3, pp. 615-619, (2000)
[5]  
Kahwash R., Leier C.V., Miller L., Role of the pulmonary artery catheter in diagnosis and management of heart failure, Heart Fail Clin, 5, 2, pp. 241-248, (2009)
[6]  
Shah M.R., O'Connor C.M., Sopko G., Hasselblad V., Califf R.M., Stevenson L.W., Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness (ESCAPE): Design and rationale, American Heart Journal, 141, 4, pp. 528-535, (2001)
[7]  
Side C.D., Gosling R.G., Non-surgical assessment of cardiac function, Nature, 232, 5309, pp. 335-336, (1971)
[8]  
Dark P.M., Singer M., The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults, Intensive Care Medicine, 30, 11, pp. 2060-2066, (2004)
[9]  
Singer M., Bennett E.D., Noninvasive optimization of left ventricular filling using esophageal Doppler, Crit Care Med, 19, 9, pp. 1132-1137, (1991)
[10]  
Madan A.K., Et al., Esophageal Doppler ultrasound monitor versus pulmonary artery catheter in the hemodynamic management of critically ill surgical patients, J Trauma, 46, 4, pp. 607-611, (1999)