Long Wavelength Fluorescence Ratiometric Zinc Biosensor

被引:0
|
作者
Hui Hui Zeng
Evgenia G. Matveeva
Andrea K. Stoddard
Carol A. Fierke
Richard B. Thompson
机构
[1] University of Maryland School of Medicine,Department of Biochemistry and Molecular Biology
[2] University of Michigan,Department of Chemistry
来源
Journal of Fluorescence | 2013年 / 23卷
关键词
Zinc ion; Fluorescence biosensor; Ratiometric; Carbonic anhydrase; FRET; Forster resonance energy transfer;
D O I
暂无
中图分类号
学科分类号
摘要
A protein-based emission ratiometric fluorescence biosensor is described that exhibits sensitivity to free zinc ion in solution down to picomolar concentrations. Ratiometric measurements are widely used to assure accurate quantitation, and emission ratios are preferred for laser scanning microscopes such as confocal fluorescence microscopes. The relatively long emission wavelengths used are well suited to studies in tissues and other matrices which exhibit significant fluorescence background, and the apo-carbonic anhydrase moiety recognizes zinc ion with high and controllable specificity.
引用
收藏
页码:375 / 379
页数:4
相关论文
共 50 条
  • [1] Long Wavelength Fluorescence Ratiometric Zinc Biosensor
    Zeng, Hui Hui
    Matveeva, Evgenia G.
    Stoddard, Andrea K.
    Fierke, Carol A.
    Thompson, Richard B.
    JOURNAL OF FLUORESCENCE, 2013, 23 (03) : 375 - 379
  • [2] An oxo-bacteriochlorin derivative for long-wavelength fluorescence ratiometric alcohol sensing
    Takano, Kosuke
    Sasaki, Shin-ichi
    Citterio, Daniel
    Tamiaki, Hitoshi
    Suzuki, Koji
    ANALYST, 2010, 135 (09) : 2334 - 2339
  • [3] Measuring picomolar intracellular exchangeable zinc in PC-12 cells using a ratiometric fluorescence biosensor
    Bozym, Rebecca A.
    Thompson, Richard B.
    Stoddard, Andrea K.
    Fierke, Carol A.
    ACS CHEMICAL BIOLOGY, 2006, 1 (02) : 103 - 111
  • [4] Excitation ratiometric fluorescent biosensor for intracellular free zinc
    Bozym, RA
    Thompson, RB
    Fierke, C
    BIOPHYSICAL JOURNAL, 2004, 86 (01) : 606A - 606A
  • [5] In situ measurement of free zinc in an ischemia model and cell culture using a ratiometric fluorescence-based biosensor
    Zeng, HH
    Bozym, RA
    Rosenthal, RE
    Fiskum, G
    Cotto-Cumba, C
    Westerburg, N
    Fierke, CA
    Stoddard, A
    Cramer, ML
    Frederickson, CJ
    Thompson, R
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS III, 2005, 5692 : 51 - 59
  • [6] Carbon-dot-based ratiometric fluorescence glucose biosensor
    Cho, Moon-Jin
    Park, Soo-Young
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 282 : 719 - 729
  • [7] Excitation ratiometric fluorescent biosensor for zinc ion at picomolar levels
    Thompson, RB
    Cramer, ML
    Bozym, R
    Fierke, CA
    JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (04) : 555 - 560
  • [8] Ratiometric Bioluminescence-Based Zinc Biosensor with Nanomolar Sensitivity
    Matveeva, Evgenia G.
    Franke, Graham
    Bourne, Leslie
    Stoddard, Andrea K.
    Fierke, Carol A.
    Thompson, Richard B.
    BIOPHYSICAL JOURNAL, 2015, 108 (02) : 492A - 492A
  • [9] Switch-conversional ratiometric fluorescence biosensor for miRNA detection
    Chen, Xian
    Xu, Ke
    Li, Jing
    Yang, Ming
    Li, Xing
    Chen, Qin
    Lu, Chunhua
    Yang, Huanghao
    BIOSENSORS & BIOELECTRONICS, 2020, 155
  • [10] A Rapid Ratiometric Fluorescence Biosensor for Detection of Ochratoxin A Based on Paper Chip
    Lin, Hao
    He, Xuan
    Chen, Yan
    Pang, Lu-Yi
    Niu, Lei
    Fu, Xiu-Li
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (09) : 1336 - 1344