Numerical investigation of rotating stall in centrifugal compressor with vaned and vaneless diffuser

被引:0
作者
Taher Halawa
Mohamed Alqaradawi
Mohamed S. Gadala
Ibrahim Shahin
Osama Badr
机构
[1] UBC-University of British Columbia,Mechanical Engineering Department
[2] Qatar University,Mechanical & Industrial Engineering Department
[3] UBC-University of British Columbia,Mechanical Engineering Department
[4] Qatar University,Mechanical and Industrial Engineering Department
[5] British University,Mechanical Engineering Department
[6] Cairo University,Mechanical Engineering Department
[7] Abu Dhabi University,Mechanical Engineering Department
[8] Benha University,Mechanical Engineering Department
来源
Journal of Thermal Science | 2015年 / 24卷
关键词
centrifugal compressors; rotating stall; surge; vaneless diffuser; vaned diffuser;
D O I
暂无
中图分类号
学科分类号
摘要
This study presents a numerical simulation of the stall and surge in a centrifugal compressor and presents a description of the stall development in two different cases. The first case is for a compressor with vaneless diffuser and the second is for a compressor with vaned diffuser of the vane island shape. The main aim of this study is to compare the flow characteristics and behavior for the two compressors near the surge operating condition and provide further understanding of the diffuser role when back flow occurs at surge. Results showed that for a location near the diffuser entrance, the amplitude of the static pressure fluctuations for the vaneless diffuser case is higher than that for the vaned diffuser case near surge condition. These pressure fluctuations in the case of the vaneless diffuser appear with a gradual decrease of the mean pressure value as a part of the surge cycle. While for the case of the vaned diffuser, the pressure drop during surge occurs faster than the case of the vaneless diffuser. Also, results indicated that during surge in the case of vaneless diffuser, there is a region with low velocity and back flow that appears as a layer connecting all impeller passages near shroud surface and this layer develops in size with time. On the other hand, for the case of vaned diffuser during surge, the low velocity regions appear in random locations in some passages and these regions expand with time towards the shroud surface. Results showed that during stall, the impeller passages are exposed to identical impact from stall cells in the case of vaneless diffuser while the stall effect varies from passage to another in the case of the vaned diffuser.
引用
收藏
页码:323 / 333
页数:10
相关论文
共 36 条
[1]  
Vo H. D.(2008)Criteria for spike initiated rotating stall Journal of Turbomachinery 130 011023-300
[2]  
Tan C. S.(2010)Spiketype compressor stall inception, detection, and control Annual Review of Fluid Mechanics 42 275-303
[3]  
Greitzer E. M.(2011)Evolution of unsteady flow near rotor tip during stall inception Journal of Thermal Science 20 294-120
[4]  
Tan C.(2007)Numerical simulation of rotating stall in a centrifugal compressor with vaned diffuser Journal of Thermal Science 16 115-47
[5]  
Day I.(2009)Stall characteristics and tip clearance effects in forward swept axial compressor rotors Journal of Thermal Science 18 40-119
[6]  
Morris S.(2012)Numerical investigation of tip clearance effects in an axial transonic compressor Journal of Thermal Science 21 109-1448
[7]  
Wadia A.(2013)Steady Air Injection Flow Control Parameters in a Transonic Axial Compressor Research Journal of Applied Sciences 5 1441-6
[8]  
Geng S.(2007)Experimental investigations of micro air injection to control rotating stall Journal of Thermal Science 16 1-89
[9]  
Lin F.(2009)High performance computing of compressor rotating stall and stall control Integrated Computer-Aided Engineering 16 75-428
[10]  
Chen J.(2001)An investigation of surge in a high-speed centrifugal compressor using digital PIV Journal of turbomachinery 123 418-undefined