Paroxysmal nocturnal hemoglobinuria (PNH): higher sensitivity and validity in diagnosis and serial monitoring by flow cytometric analysis of reticulocytes

被引:0
作者
Britta Höchsmann
Markus Rojewski
Hubert Schrezenmeier
机构
[1] Institute for Clinical Transfusion Medicine and Immunogenetics Ulm,DRK
[2] University of Ulm,Blood Donor Service, Baden
来源
Annals of Hematology | 2011年 / 90卷
关键词
PNH; Paroxysmal nocturnal hemoglobinuria; Flow cytometry; Immunophenotyping; Glycosylphophatidyl-inositol anchor; GPI deficiency; Reticulocytes;
D O I
暂无
中图分类号
学科分类号
摘要
Flow cytometric analysis of GPI-anchored proteins (GPI-AP) is the gold standard for diagnosis of paroxysmal nocturnal hemoglobinuria (PNH). Due to therapy options and the relevance of GPI-deficient clones for prognosis in aplastic anaemia detection of PNH is gaining importance. However, no generally accepted standard has been established. This study analysed the usefulness of a flow cytometric panel with CD58, CD59 on reticulocytes and erythrocytes, CD24/CD66b and CD16, FLAER on granulocytes and CD14, and CD48 on monocytes. Actual cut-off (mean + 2 SD) for GPI-deficient cells was established in healthy blood donors. We studied 1,296 flow cytometric results of 803 patients. Serial monitoring was analysed during a median follow-up of 1,039 days in 155 patients. Of all, 22% and 48% of 155 follow-up patients. showed significant GPI-AP-deficiency at time of initial analyses. During follow-up in 9%, a new PNH diagnosis, and in 28%, a significant change of size or lineage involvement was demonstrated. Highly significant correlations for GPI-AP deficiency were found within one cell lineage (r2 = 0.61–0.95, p < 0.0001) and between the different cell lineages (r2 = 0.49–0.88, p < 0.0001). Especially for detection of small GPI-deficient populations, reticulocytes and monocytes proved to be sensitive diagnostic tools. Our data showed superiority of reticulocyte analyses compared with erythrocyte analyses due to transfusion and hemolysis independency especially in cases with small GPI-deficient populations. In conclusion, a screening panel of at least two different GPI-AP markers on granulocytes, erythrocytes, and reticulocytes provides a simple and rapid method to detect even small GPI-deficient populations. Among the markers in our panel, CD58 and CD59 on reticulocytes, CD24/66b, and eventually FLAER on granulocytes as well as CD14 on monocytes were most effective for flow cytometric diagnosis of GPI deficiency.
引用
收藏
页码:887 / 899
页数:12
相关论文
共 156 条
[1]  
Dacie JV(1963)Paroxysmal nocturnal haemoglobinuria Proc R Soc Med 56 587-596
[2]  
Oni SB(1970)Paroxysmal nocturnal hemoglobinuria: evidence of monoclonal origin of abnormal red cells Blood 36 145-152
[3]  
Osunkoya BO(1993)The cloning of PIG-A, a component in the early step of GPI-anchor biosynthesis Science 259 1318-1320
[4]  
Luzzatto L(2003)The spectrum of PIG-A mutations in aplastic anemia/paroxysmal nocturnal hemoglobinuria: a high incidence of multiple mutations and evidence of a mutational hot spot Blood 101 2833-2841
[5]  
Myata T(1994)Paroxysmal nocturnal hemoglobinuria is caused by somatic mutations in the PIG-A gene EMBO J 13 110-117
[6]  
Takeda J(1995)Natural history of paroxysmal nocturnal hemoglobinuria N Eng J 333 1253-1258
[7]  
Iida Y(1992)Two distinct patterns of glycosylphosphatidylinositol (GPI) linked protein deficiency in the red cells of patients with paroxysmal nocturnal haemoglobinuria Br J Haematol 80 399-405
[8]  
Yamada N(2008)Paroxysmal nocturnal hemoglobinuria: natural history of disease subcategories Blood 112 3099-3106
[9]  
Inoue N(2008)Detailed immunophenotypic characterization of different major and minor subsets of peripheral blood cells in patients with paroxysmal nocturnal hemoglobinuria Transfusion 48 1403-1414
[10]  
Takahashi M(2003)Flow cytometric analysis of GPI-deficient cells for the diagnosis of paroxysmal nocturnal hemoglobinuria (PNH) J Lab Med 27 257-265