Sequential Injection Amperometric Determination of Glucose in Saliva Using a Screen-Printed Electrode Modified with a Gold–Cobalt Binary System

被引:0
作者
L. G. Shaidarova
I. A. Chelnokova
I. A. Gafiatova
A. V. Gedmina
H. C. Budnikov
机构
[1] Butlerov Institute of Chemistry,
[2] Kazan Federal University,undefined
来源
Journal of Analytical Chemistry | 2023年 / 78卷
关键词
chemically modified electrodes; planar electrode; cobalt and gold particles; gold–cobalt binary system; glucose electrooxidation; sequential injection analysis; amperometric detector;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:372 / 377
页数:5
相关论文
共 37 条
  • [21] Flow-Injection Amperometric Determination of Adrenalin, Melatonin, and Cortisol on an Electrode Modified with a Gold-Palladium Binary System and a Nafion Film
    Shaidarova, L. G.
    Chelnokova, I. A.
    Leksina, Yu. A.
    Khairullina, D. Yu.
    Budnikov, H. C.
    INORGANIC MATERIALS, 2023, 59 (14) : 1474 - 1481
  • [22] Flow-Injection Amperometric Determination of Ceftriaxone, Cefotaxime, and Cefoperazone Using an Electrode Modified with a Binary System of Gold Particles and Mixed-Valent Ruthenium Oxides
    Shaidarova, L. G.
    Chelnokova, I. A.
    Il'ina, M. A.
    Budnikov, H. C.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (08) : 1159 - 1165
  • [23] Flow injection amperometric determination of acetaminophen at a gold nanoparticle modified carbon paste electrode
    Zemin Xu
    Qu Yue
    Zhenjing Zhuang
    Dan Xiao
    Microchimica Acta, 2009, 164 : 387 - 393
  • [24] Flow injection amperometric determination of acetaminophen at a gold nanoparticle modified carbon paste electrode
    Xu, Zemin
    Yue, Qu
    Zhuang, Zhenjing
    Xiao, Dan
    MICROCHIMICA ACTA, 2009, 164 (3-4) : 387 - 393
  • [25] A sensitive Cu(salophen) modified screen-printed electrode for simultaneous determination of dopamine and uric acid
    Beitollahi, Hadi
    Tajik, Somayeh
    Aflatoonian, Mohammad Reza
    Makarem, Asghar
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2022, 12 (01): : 199 - 208
  • [26] Amperometric Detection of Caffeine and Paracetamol on A Dual Screen Printed Electrode Modified with Mixed-Valence Ruthenium and Cobalt Oxides in Flow-Injection Analysis
    Shaidarova, L. G.
    Chelnokova, I. A.
    Il'ina, M. A.
    Gedmina, A. V.
    Budnikov, H. C.
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2016, 7 (06): : 2884 - 2891
  • [27] Sequential injection differential pulse voltammetric method based on screen printed carbon electrode modified with carbon nanotube/Nafion for sensitive determination of paraquat
    Chuntib, Prakit
    Themsirimongkon, Suwaphid
    Saipanya, Surin
    Jakmunee, Jaroon
    TALANTA, 2017, 170 : 1 - 8
  • [28] Determination of trace heavy metals in herbs by sequential injection analysis-anodic stripping voltammetry using screen-printed carbon nanotubes electrodes
    Injang, Uthaitip
    Noyrod, Peeyanun
    Siangproh, Weena
    Dungchai, Wijitar
    Motomizu, Shoji
    Chailapakul, Orawon
    ANALYTICA CHIMICA ACTA, 2010, 668 (01) : 54 - 60
  • [29] Sequential Injection Assisted Stripping Chronopotentiometry at Screen Printed Gold Electrodes for Determination of Hg(II) in Adsorption Studies
    do Nascimento, Fernando Henrique
    Masini, Jorge Cesar
    ANALYTICAL LETTERS, 2016, 49 (05) : 699 - 710
  • [30] The effect of laser surface texturing on ZnO/MWCNT nanocomposite modified screen-printed carbon electrode for non-enzymatic glucose biosensor
    Jazi, Hamidreza Kaviani
    Sarafbidabad, Mohsen
    Ben Henda, Mouna
    Ahmadipour, Mohsen
    DIAMOND AND RELATED MATERIALS, 2025, 151