Sequential Injection Amperometric Determination of Glucose in Saliva Using a Screen-Printed Electrode Modified with a Gold–Cobalt Binary System

被引:0
|
作者
L. G. Shaidarova
I. A. Chelnokova
I. A. Gafiatova
A. V. Gedmina
H. C. Budnikov
机构
[1] Butlerov Institute of Chemistry,
[2] Kazan Federal University,undefined
来源
Journal of Analytical Chemistry | 2023年 / 78卷
关键词
chemically modified electrodes; planar electrode; cobalt and gold particles; gold–cobalt binary system; glucose electrooxidation; sequential injection analysis; amperometric detector;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:372 / 377
页数:5
相关论文
共 50 条
  • [1] Sequential Injection Amperometric Determination of Glucose in Saliva Using a Screen-Printed Electrode Modified with a Gold-Cobalt Binary System
    Shaidarova, L. G.
    Chelnokova, I. A.
    Gafiatova, I. A.
    Gedmina, A. V.
    Budnikov, H. C.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 78 (03) : 372 - 377
  • [2] Dual Screen-Printed Electrode Modified by Gold - Palladium Binary System for Flow-Injection Amperometric Determination of Dopamine and Ascorbic Acid
    Shaidarova, L. G.
    Leksina, Y. A.
    Chelnokova, I. A.
    Il'ina, M. A.
    Gedmina, A. V.
    Budnikov, H. C.
    UCHENYE ZAPISKI KAZANSKOGO UNIVERSITETA-SERIYA ESTESTVENNYE NAUKI, 2018, 160 (01): : 40 - 53
  • [3] Gold Nanoparticles Decorated on Carbon Nanotube Modified Screen-printed Electrode for Flow Injection Amperometric Determination of Methyldopa
    Upan, Jantima
    Themsirimongkon, Suwaphid
    Saipanya, Surin
    Jakmunee, Jaroon
    CHIANG MAI JOURNAL OF SCIENCE, 2019, 46 (03): : 537 - 546
  • [4] Flow injection amperometric determination of isoniazid using a screen-printed carbon electrode modified with silver hexacyanoferrates nanoparticles
    de Oliveira, Paulo Roberto
    Oliveira, Marcela Mohallem
    Zarbin, Aldo J. G.
    Marcolino-Junior, Luiz Humberto
    Bergamini, Marcio F.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 795 - 802
  • [5] Amperometric Detection of Tryptophane and Pyridoxine on a Dual Screen-Printed Electrode Modified by Gold Nanoparticles in a Flow-Injection System
    L. G. Shaidarova
    I. A. Chelnokova
    M. A. Il’ina
    Yu. A. Leksina
    H. C. Budnikov
    Journal of Analytical Chemistry, 2019, 74 : 584 - 590
  • [6] A highly sensitive flow injection amperometric glucose biosensor using a gold nanoparticles/polytyramine/Prussian blue modified screen-printed carbon electrode
    Khumngern, Suntisak
    Jirakunakorn, Ratchaneekorn
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    BIOELECTROCHEMISTRY, 2021, 138
  • [7] A highly sensitive flow injection amperometric glucose biosensor using a gold nanoparticles/polytyramine/Prussian blue modified screen-printed carbon electrode
    Khumngern, Suntisak
    Jirakunakorn, Ratchaneekorn
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    Bioelectrochemistry, 2021, 138
  • [8] Simultaneous determination of maltose and glucose using a screen-printed electrode system
    Ge, F
    Zhang, XE
    Zhang, ZP
    Zhang, XM
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4): : 333 - 339
  • [9] Flow injection amperometric determination of procaine in pharmaceutical formulation using a screen-printed carbon electrode
    Bergamini, Marcio F.
    Santos, Andre L.
    Stradiotto, Nelson R.
    Zanoni, Maria Valnice B.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (01) : 315 - 319
  • [10] Glucose biosensors based on a gold nanodendrite modified screen-printed electrode
    Liu, Hsi-Chien
    Tsai, Chung-Che
    Wang, Gou-Jen
    NANOTECHNOLOGY, 2013, 24 (21)