The 90% minimum effective volume of 0.5 ropivacaine for ultrasound-guided supraclavicular brachial plexus block: A biased coin up-and-down design; [Das 90 %ige minimale effektive Volumen von 0,5 Ropivacain für die ultraschallgesteuerte supraklavikuläre Plexus-brachialis-Blockade: Ein „biased coin-up-and-down design“]

被引:0
作者
Xuan Q. [1 ,3 ]
Pan R. [2 ]
Wang A. [3 ]
Li R. [3 ]
Yang X. [3 ]
Yin G. [3 ]
机构
[1] Department of Anesthesiology, The 960th Hospital of PLA, Jinan
[2] People’s Hospital of Juye County, Shandong Province, Heze
[3] Department of Anesthesiology, The First Affiliated Hospital of Dali University, Yunnan Province, Dali
来源
Die Anaesthesiologie | 2023年 / 72卷 / Suppl 1期
关键词
Biased coin up-and-down design; Brachial plexus block; Cross-sectional nerve area; Ropivacaine; Supraclavicular brachial plexus;
D O I
10.1007/s00101-023-01344-7
中图分类号
学科分类号
摘要
Background: Ultrasound-guided supraclavicular brachial plexus block is widely used in upper limb surgery; however, it requires a higher dose (20–30 mL) of local anesthetic. In this study, we aimed to determine the 90% minimum effective volume for ultrasound-guided supraclavicular brachial plexus block. Methods: All patients received an ultrasound-guided two-point injection of 0.5% ropivacaine at a starting volume of 0.18 mL/mm2 cross-sectional nerve area. In cases of a successful block, the next patient had the same volume with a probability of 0.89, and the volume was reduced by 0.04 mL/mm2 cross-sectional nerve area with a probability of 0.11. When the block failed, the dose was increased by 0.04 mL/mm2 cross-sectional nerve area. After 45 cases of successful blocks, the 90% minimum effective volume of local anesthetic was calculated using the centered isotonic regression function. Results: Centered isotonic regression analysis resulted in a 90% minimum effective volume and a 95% confidence interval of 0.189 mL/mm2 and 0.176–0.225 mL/mm2 for the supraclavicular brachial plexus block. Conclusion: A good blocking effect can be achieved with 0.189 mL/mm2 of 0.5% ropivacaine with more precise dosing, thereby reducing the risk of local anesthetic poisoning. © 2023, The Author(s), under exclusive licence to Springer Medizin Verlag GmbH, ein Teil von Springer Nature.
引用
收藏
页码:39 / 43
页数:4
相关论文
共 11 条
[1]  
Datta R., Agrawal J., Narula G., Et al., A fluoroscopic assessment of brachial plexus block by the supraclavicular approach: Have we been overmedicating?, Med J Armed Forces India, 76, 4, pp. 410-417, (2019)
[2]  
Latzke D., Marhofer P., Zeitlinger M., Et al., Minimal local anaesthetic volumes for sciatic nerve block: evaluation of ED 99 in volunteers, Br J Anaesth, 104, 2, pp. 239-244, (2009)
[3]  
Haun D.W., Cho J.C., Clark T.B., Et al., Normative cross-sectional area of the brachial plexus and subclavian artery using ultrasonography, J Manipulative Physiol Ther, (2009)
[4]  
Techasuk W., Gonzalez A.P., Bernucci F., Cupido T., Finlayson R.J., Tran D.Q., A randomized comparison between double-injection and targeted intracluster-injection ultrasound-guided supraclavicular brachial plexus block, Anesth Analg, 118, 6, pp. 1363-1369, (2014)
[5]  
Stylianou M., Flournoy N., Dose finding using the biased coin up-and-down design and isotonic regression, Biometrics, 58, 1, pp. 171-177, (2002)
[6]  
Gupta P.K., Pace N.L., Hopkins P.M., Effect of body mass index on the ED50 volume of bupivacaine 0.5 % for supraclavicular brachial plexus block, Br J Anaesth, 104, 4, pp. 490-495, (2010)
[7]  
Fang G., Wan L., Mei W., Et al., The minimum effective concentration (MEC90) of ropivacaine for ultrasound-guided supraclavicular brachial plexus block, Anaesthesia, 71, 6, pp. 700-705, (2016)
[8]  
Fang G., Wan L., Li S., Et al., An optimal dose of ropivacaine for ultrasound-guided supraclavicular brachial plexus block: a biased coin design, Eur J Anaesthesiol, 38, 2, pp. 186-187, (2021)
[9]  
Eichenberger U., Stockli S., Marhofer P., Et al., Minimal local anesthetic volume for peripheral nerve block: a new ultrasound-guided, nerve dimension-based method, Reg Anesth Pain Med, 34, 3, pp. 242-246, (2009)
[10]  
Renes S.H., Spoormans H.H., Gielen M.J., Et al., Hemidiaphragmatic paresis can be avoided in ultrasound-guided supraclavicular brachial plexus block, Reg Anesth Pain Med, (2009)