pH-sensitive response of a highly photoluminescent MoS2 nanohybrid material and its application in the nonenzymatic detection of H2O2

被引:0
作者
Neema Pallikkarathodi Mani
Jobin Cyriac
机构
[1] Indian Institute of Space Science and Technology,Department of Chemistry
来源
Analytical and Bioanalytical Chemistry | 2019年 / 411卷
关键词
MoS; nanohybrid; pH response; H; O; detection; Glucose detection; Fluorescent sensor;
D O I
暂无
中图分类号
学科分类号
摘要
The mechanism behind the variation in the photoluminescence (PL) of a MoS2 nanohybrid material with pH was investigated. Highly fluorescent MoS2 quantum dots dispersed across MoS2 nanosheets (MoS2 QDNS) were synthesized by a hydrothermal route in the presence of NaOH. Upon reducing the pH from 13 to 6.5, the PL intensity was markedly quenched. The removal of dangling sulfur atoms by adding mineral acids could be a plausible mechanism for this PL quenching, together with the inner filter effect and Förster resonance energy transfer due to the resulting species. A label-free turn-on fluorescence sensor for H2O2 was developed using this hybrid material. The PL of the acidified MoS2 QDNS at pH 6.5 increased (i.e., recovered) linearly with the concentration of H2O2. The dynamic range of the sensor was found to be 2–94 μM with a limit of detection (LOD) of 2 μM. This sensing strategy was also extended for the detection of glucose by appending glucose oxidase (GOx) as a catalyst. In the presence of GOx, glucose oxidizes to gluconic acid and H2O2, so the original level of glucose can be estimated by determining the H2O2 present. The absence of a complicated enzyme immobilization step is the prime advantage of the present glucose sensor. The current work exemplifies the utility of MoS2-based nanoparticle systems in the biological sensor domain.
引用
收藏
页码:5481 / 5488
页数:7
相关论文
共 120 条
[1]  
Shu X(2007)H Anal Chem 79 3695-3702
[2]  
Chen Y(2011)O Chem Commun 47 11327-11329
[3]  
Yuan H(2012) sensor based on the room-temperature phosphorescence of nano TiO ACS Nano 6 3767-3775
[4]  
Gao S(2010)/SiO Anal Chem 82 5205-5210
[5]  
Xiao D(2014) composite Anal Chem 86 9459-9465
[6]  
Wu P(1986)Enhancing the electrochemical reduction of hydrogen peroxide based on nitrogen-doped graphene for measurement of its releasing process from living cells Proc Natl Acad Sci U S A 83 4514-4518
[7]  
Cai Z(2005)Cerium oxide nanoparticles protect cardiac progenitor cells from oxidative stress Proc Natl Acad Sci U S A 102 13604-13609
[8]  
Gao Y(2011)Voltammetric detection of hydrogen peroxide at carbon fiber microelectrodes Analyst. 136 3550-3556
[9]  
Zhang H(2017)Highly sensitive graphene–Pt nanocomposites amperometric biosensor and its application in living cell H Sensors Actuators B Chem 252 183-190
[10]  
Cai C(2011)O J Am Chem Soc 133 10629-10637