Radiation dose reduction in the setting of cryoballoon ablation for atrial fibrillation: the value of optimized fluoroscopy settings and intracardiac echocardiography

被引:0
作者
Vedran Velagic
Giacomo Mugnai
Ivan Prepolec
Vedran Pasara
Mislav Puljevic
Borka Pezo-Nikolic
Davor Puljević
Carlo de Asmundis
Gian-Battista Chierchia
Davor Milicic
机构
[1] University Hospital Center Zagreb,Department of Cardiovascular Diseases
[2] University of Zagreb School of Medicine,Electrophysiology and Cardiac Pacing, Division of Cardiology
[3] University Hospital of Verona,Heart Rhythm Management Centre
[4] UZ Brussel-VUB,undefined
来源
The International Journal of Cardiovascular Imaging | 2023年 / 39卷
关键词
Atrial fibrillation; Catheter ablation; Cryoballoon; Radiation dose reduction;
D O I
暂无
中图分类号
学科分类号
摘要
Cryoballoon (CB) has proven to be very effective in the percutaneous treatment of atrial fibrillation (AF). CB ablation is still hampered by X-ray exposure and the doses applied are consistently higher if compared to radiofrequency ablation. All patients who underwent CB ablation between 2015 and 2020 were analysed. Intracardiac echography was consistently used for transeptal puncture. To demonstrate the differences in radiation exposure 3 groups of 50 consecutive patients were selected. In the first group (G1) 3D rotational angiography (3DRA) was used as an intraprocedural imaging method. In the second group (G2), traditional X-ray imaging was used and frame rates both for fluoro and cine modes of diascopy were lowered. In the third group (G3) only 2–3 frames per second were used, cine mode was abandoned and the grid was removed from the X-ray detector. A total of 150 patients were included (76% males, mean age 57.3 ± 11.5 years). A dramatic reduction of radiation dose was obtained from 9585 ± 5610 µGy/m2 in G1 to 2469 ± 2002 µGy/m2 in G2 and finally 227.1 ± 360 µGy/m2 in G3 (p < 0.0001). There was also a significant decrease of procedural and fluoroscopy times. No difference in major complications and midterm outcomes was found between the groups. By following a few relatively simple steps (omitting the pre-procedural imaging, removing grid from the X-ray detector and using very low frame rates) CB ablation could be performed with ultralow radiation exposure without compromising the safety of efficacy of the procedure.
引用
收藏
页码:245 / 254
页数:9
相关论文
共 125 条
  • [1] Hindricks G(2021)2020 ESC guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS): the task force for the diagnosis and management of atrial fibrillation of the European Society of Cardiology (ESC) developed with the special contribution of the European Heart Rhythm Association (EHRA) of the ESC Eur Heart J 42 373-498
  • [2] Potpara T(2017)Learning curve using the second-generation cryoballoon ablation J Cardiovasc Med (Hagerstown) 18 518-527
  • [3] Dagres N(2015)Acute and long-term outcomes of catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: a multicenter experience J Cardiovasc Electrophysiol 26 832-839
  • [4] Arbelo E(2018)Cryoballoon versus radiofrequency ablation for paroxysmal atrial fibrillation: a meta-analysis of randomized controlled trials Clin Res Cardiol 107 658-669
  • [5] Bax JJ(2020)Meta-analysis comparing cryoballoon versus radiofrequency as first ablation procedure for atrial fibrillation Am J Cardiol 125 1170-1179
  • [6] Blomström-Lundqvist C(2021)Integrated 3D intracardiac ultrasound imaging with detailed pulmonary vein delineation guided fluoroless ablation of atrial fibrillation Pacing Clin Electrophysiol 44 1487-1496
  • [7] Velagić V(2017)Cryoballoon vs. radiofrequency ablation for paroxysmal atrial fibrillation: an updated meta-analysis of randomized and observational studies Europace 19 378-384
  • [8] de Asmundis C(2004)Radiation exposure during catheter ablation of atrial fibrillation Circulation 110 3003-3010
  • [9] Mugnai G(2018)Significant reduction of radiation exposure in cryoballoon-based pulmonary vein isolation Europace 20 608-613
  • [10] Hünük B(2020)Reducing radiation exposure in second-generation cryoballoon ablation without compromising clinical outcome J Interv Cardiac Electrophysiol 43 1538-1545