Selective determination of hydroquinone in the presence of catechol based on over-oxidized poly(hydroquinone)

被引:0
|
作者
Yongsheng Zhou
Xiaolin Ren
Chao Sheng
Xiaohui Chen
Yong Kong
Yongxin Tao
Zhidong Chen
机构
[1] Changzhou University,Institute of Petrochemical Technology
[2] Key Laboratory of Fine Petrochemicals of Jiangsu Province,undefined
来源
Journal of Solid State Electrochemistry | 2012年 / 16卷
关键词
Selective determination; Hydroquinone; Catechol; Poly(hydroquinone); Over-oxidation;
D O I
暂无
中图分类号
学科分类号
摘要
Selective determination of hydroquinone (HQ) in the presence of catechol (CC) was developed at an over-oxidized poly(hydroquinone) (PHQ) electrode. The electrochemical polymerization of HQ was carried out by potentiostatic method on a glassy carbon electrode. The resulting PHQ was over-oxidized in 0.10 mol/L NaOH solution and thus poly(p-benzoquinone) was obtained. Two dihydroxybenzene isomers, HQ and CC, show different voltammetric behavior at the over-oxidized PHQ electrode. The peak current of HQ is much larger than that of CC with the same concentration, which is attributed to the different position of the hydroxyl groups in benzene ring of the two isomers. The results from electrochemical impedance spectroscopy also demonstrates that the over-oxidized PHQ electrode has a stronger affinity for HQ over CC.
引用
收藏
页码:3159 / 3164
页数:5
相关论文
共 50 条
  • [22] Disposable graphite paper based sensor for sensitive simultaneous determination of hydroquinone and catechol
    Fan, Limei
    Li, Xueyan
    Kan, Xianwen
    ELECTROCHIMICA ACTA, 2016, 213 : 504 - 511
  • [23] Simultaneous Determination of Hydroquinone and Catechol at Poly-histidine Film Modified Glassy Carbon Electrode
    Yang, Qiu-xia
    Sui, Wei-ping
    Fan, Da-wei
    Li, Guo-bao
    ADVANCES IN CHEMICAL ENGINEERING III, PTS 1-4, 2013, 781-784 : 89 - 92
  • [24] Highly sensitive and simultaneous determination of hydroquinone and catechol at poly(thionine) modified glassy carbon electrode
    Ahammad, A. J. Saleh
    Rahman, Md Mahbubur
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    ELECTROCHIMICA ACTA, 2011, 56 (14) : 5266 - 5271
  • [25] Selective sensing of catechol and hydroquinone based on poly(3,4-ethylenedioxythiophene)/nitrogen-doped graphene composites
    Si, Weimeng
    Lei, Wu
    Han, Zhen
    Hao, Qingli
    Zhang, Yuehua
    Xia, Mingzhu
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 199 : 154 - 160
  • [26] Influence of micelles on the electrochemical behaviors of catechol and hydroquinone and their simultaneous determination
    Juan Peng
    Zuo-Ning Gao
    Analytical and Bioanalytical Chemistry, 2006, 384 : 1525 - 1532
  • [27] Influence of micelles on the electrochemical behaviors of catechol and hydroquinone and their simultaneous determination
    Peng, J
    Gao, ZN
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (7-8) : 1525 - 1532
  • [28] Simultaneous Determination of Hydroquinone and Catechol by Differential Alternative Pulses Voltammetry
    Ayala, Alan
    Stoytcheva, Margarita
    Zlatev, Roumen
    Velkova, Zdravka
    Gochev, Velizar
    Valdez, Benjamin
    Montero, Gisela
    ELECTROANALYSIS, 2018, 30 (09) : 1913 - 1917
  • [29] Simultaneous Determination of Hydroquinone and Catechol at an Activated Glassy Carbon Electrode
    Ahammad, A. J. Saleh
    Sarker, Subrata
    Rahman, Md Aminur
    Lee, Jae-Joon
    ELECTROANALYSIS, 2010, 22 (06) : 694 - 700
  • [30] Multiwall carbon nanotubes-poly(diallyldimethylammonium chloride)-graphene hybrid composite film for simultaneous determination of catechol and hydroquinone
    Song, Daimin
    Xia, Jianfei
    Zhang, Feifei
    Bi, Sai
    Xiang, Wenjun
    Wang, Zonghua
    Xia, Lin
    Xia, Yanzhi
    Li, Yanhui
    Xia, Linhua
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 206 : 111 - 118