Management of axitinib (AG-013736)-induced fatigue and thyroid dysfunction, and predictive biomarkers of axitinib exposure: results from phase I studies in Japanese patients

被引:0
作者
Yutaka Fujiwara
Naomi Kiyota
Naoko Chayahara
Akiyuki Suzuki
Yoshiko Umeyama
Toru Mukohara
Hironobu Minami
机构
[1] Kobe University Hospital,Medical Oncology/Hematology, Department of Medicine
[2] Pfizer Japan Inc,undefined
[3] Kobe University Hospital,undefined
来源
Investigational New Drugs | 2012年 / 30卷
关键词
Axitinib; Fatigue; Thyroid dysfunction; Biomarker; Pharmacokinetics; Vascular endothelial growth factor receptor;
D O I
暂无
中图分类号
学科分类号
摘要
Background Axitinib is an oral, potent and selective inhibitor of vascular endothelial growth factor receptors (VEGFRs) 1, 2 and 3. We report on data obtained from 18 Japanese patients with advanced solid tumors in two phase I trials that evaluated the safety, pharmacokinetics and antitumor activity of axitinib and also examined potential biomarkers. Methods Six patients received a single 5-mg dose of axitinib followed by 5 mg twice daily (BID), and an additional six patients received axitinib 5 mg BID only. Another six patients received axitinib at 5-mg, 7-mg and 10-mg single doses followed by 5 mg BID. Results Plasma pharmacokinetics following single doses of axitinib was generally linear. Common treatment-related adverse events were fatigue (83%), anorexia (72%), diarrhea (67%), hand–foot syndrome (67%) and hypertension (61%). Sixteen patients (89%) experienced thyroid-stimulating hormone (TSH) elevation. Grade 3/4 toxicities included hypertension (33%) and fatigue (28%). No grade 3/4 fatigue occurred in patients who started thyroid hormone replacement therapy when TSH was elevated. Thyroglobulin elevation was observed in all patients who continued treatment with axitinib for ≥3 months. Abnormal TSH correlated with exposure to axitinib (r = 0.72). Decrease in soluble (s) VEGFR-2 levels significantly correlated with exposure to axitinib (r = –0.94). Axitinib showed antitumor activity across multiple tumor types. Conclusions Axitinib-related thyroid dysfunction could be due to a direct effect on the thyroid gland. Grade 3/4 fatigue and hypothyroidism appear to be controllable with use of thyroid hormone replacement therapy. sVEGFR-2 and TSH may act as biomarkers of axitinib plasma exposure.
引用
收藏
页码:1055 / 1064
页数:9
相关论文
共 195 条
[61]  
Limentani S(undefined)undefined undefined undefined undefined-undefined
[62]  
Sandler A(undefined)undefined undefined undefined undefined-undefined
[63]  
Vokes E(undefined)undefined undefined undefined undefined-undefined
[64]  
Kim S(undefined)undefined undefined undefined undefined-undefined
[65]  
Liau K(undefined)undefined undefined undefined undefined-undefined
[66]  
Bycott P(undefined)undefined undefined undefined undefined-undefined
[67]  
Olszanski AJ(undefined)undefined undefined undefined undefined-undefined
[68]  
von Pawel J(undefined)undefined undefined undefined undefined-undefined
[69]  
Cohen EE(undefined)undefined undefined undefined undefined-undefined
[70]  
Rosen LS(undefined)undefined undefined undefined undefined-undefined