Seismic response of reinforced concrete walls with lap splices

被引:0
|
作者
Enrique Villalobos
David Escolano-Margarit
Ana Luisa Ramírez-Márquez
Santiago Pujol
机构
[1] Walter P Moore,Department of Mechanics of Structures
[2] University of Granada,Department of Civil Engineering
[3] Purdue University,Department of Civil and Structural Engineering
[4] The University of Sheffield,undefined
来源
关键词
Shear walls; Lap splices; Seismic response; Cyclic loading;
D O I
暂无
中图分类号
学科分类号
摘要
Six large-scale reinforced concrete structural walls were subjected to increasing displacement reversals up to failure. The effects of lap splices, splice length (60 bar diameters and 40 bar diameters), and boundary-element confinement were studied. The aspect ratio of the test walls was 2.2. Although no lap-splice failures occurred, the lap splices caused detrimental effects on the wall response to lateral loads. The measured drift capacity ranged from 2.5 to 3% for the walls without lap splices and from 1.5 to 2% for the walls with lap splices. Increases in drift capacity caused by the boundary-element confining reinforcement ranged between 20 and 67%. Tensile unit strain concentration was observed at the base of walls with lap splices. The relative increment in tensile unit strains was approximately 100%. Compressive unit strains were not observed to be sensitive to the presence of the lap splices.