Semi-Automated Quantification of Finger Joint Space Narrowing Using Tomosynthesis in Patients with Rheumatoid Arthritis

被引:0
|
作者
Shota Ichikawa
Tamotsu Kamishima
Kenneth Sutherland
Hideki Kasahara
Yuka Shimizu
Motoshi Fujimori
Nobutoshi Yasojima
Yohei Ono
Takahiko Kaneda
Takao Koike
机构
[1] Hokkaido University,Graduate School of Health Sciences
[2] Hokkaido University,Faculty of Health Sciences
[3] Hokkaido University,Graduate School of Medicine
[4] Sapporo Medical Center NTT EC,Department of Rheumatology
[5] Hokkaido University,Division of Rheumatology, Endocrinology and Nephrology, Graduate School of Medicine
[6] Hokkaido University,Department of Health Sciences
[7] Sapporo Medical Center NTT EC,Department of Radiology
[8] Sapporo Medical Center NTT EC,undefined
来源
Journal of Digital Imaging | 2017年 / 30卷
关键词
Computer-aided diagnosis; Conventional radiography; Tomosynthesis; Rheumatoid arthritis; Joint space narrowing;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of the study is to validate the semi-automated method using tomosynthesis images for the assessment of finger joint space narrowing (JSN) in patients with rheumatoid arthritis (RA), by using the semi-quantitative scoring method as the reference standard. Twenty patients (14 females and 6 males) with RA were included in this retrospective study. All patients underwent radiography and tomosynthesis of the bilateral hand and wrist. Two rheumatologists and a radiologist independently scored JSN with two modalities according to the Sharp/van der Heijde score. Two observers independently measured joint space width on tomosynthesis images using an in-house semi-automated method. More joints with JSN were revealed with tomosynthesis score (243 joints) and the semi-automated method (215 joints) than with radiography (120 joints), and the associations between tomosynthesis scores and radiography scores were demonstrated (P < 0.001). There was significant, negative correlation between measured joint space width and tomosynthesis scores with r = −0.606 (P < 0.001) in metacarpophalangeal joints and r = −0.518 (P < 0.001) in proximal interphalangeal joints. Inter-observer and intra-observer agreement of the semi-automated method using tomosynthesis images was in almost perfect agreement with intra-class correlation coefficient (ICC) values of 0.964 and 0.963, respectively. The semi-automated method using tomosynthesis images provided sensitive, quantitative, and reproducible measurement of finger joint space in patients with RA.
引用
收藏
页码:369 / 375
页数:6
相关论文
共 50 条
  • [1] Semi-Automated Quantification of Finger Joint Space Narrowing Using Tomosynthesis in Patients with Rheumatoid Arthritis
    Ichikawa, Shota
    Kamishima, Tamotsu
    Sutherland, Kenneth
    Kasahara, Hideki
    Shimizu, Yuka
    Fujimori, Motoshi
    Yasojima, Nobutoshi
    Ono, Yohei
    Kaneda, Takahiko
    Koike, Takao
    JOURNAL OF DIGITAL IMAGING, 2017, 30 (03) : 369 - 375
  • [2] Automatic Quantification of Joint Space Narrowing and Erosions in Rheumatoid Arthritis
    Langs, Georg
    Peloschek, Philipp
    Bischof, Horst
    Kainberger, Franz
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (01) : 151 - 164
  • [3] Joint space narrowing progression quantification with joint angle correction in rheumatoid arthritis
    Ou, Yafei
    Ambalathankandy, Prasoon
    Furuya, Ryunosuke
    Kawada, Seiya
    Kamishima, Tamotsu
    Ikebe, Masayuki
    2022 14TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2022), 2022,
  • [4] Application of ImageJ Software for the Quantification of Hand Joint Space Narrowing in Patients with Rheumatoid Arthritis
    Nui Nguyen Minh
    Nga Phi Thi Nguyen
    Chau Nguyen Ngoc
    Tien Tran Duy
    Thong Nguyen Huy
    Binh Nhu Do
    Tien Tran Viet
    CURRENT RHEUMATOLOGY REVIEWS, 2022, 18 (02) : 136 - 143
  • [5] A reliability study using computer-based analysis of finger joint space narrowing in rheumatoid arthritis patients
    Katsuya Hatano
    Tamotsu Kamishima
    Kenneth Sutherland
    Masaru Kato
    Ikuma Nakagawa
    Shota Ichikawa
    Keisuke Kawauchi
    Shota Saitou
    Masaya Mukai
    Rheumatology International, 2017, 37 : 189 - 195
  • [6] AUTOMATIC RADIOGRAPHIC QUANTIFICATION OF JOINT SPACE NARROWING PROGRESSION IN RHEUMATOID ARTHRITIS USING POC
    Ou, Yafei
    Ambalathankandy, Prasoon
    Shimada, Takeshi
    Kamishima, Thmotsu
    Ikebe, Masayuki
    2019 IEEE 16TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2019), 2019, : 1183 - 1187
  • [7] A reliability study using computer-based analysis of finger joint space narrowing in rheumatoid arthritis patients
    Hatano, Katsuya
    Kamishima, Tamotsu
    Sutherland, Kenneth
    Kato, Masaru
    Nakagawa, Ikuma
    Ichikawa, Shota
    Kawauchi, Keisuke
    Saitou, Shota
    Mukai, Masaya
    RHEUMATOLOGY INTERNATIONAL, 2017, 37 (02) : 189 - 195
  • [8] Feasibility study of semi-automated measurements of finger joint space widths
    Pfeil, Alexander
    Sommerfeld, Julia
    Froeber, Rosemarie
    Lehmann, Gabriele
    Malich, Ansgar
    Hansch, Andreas
    Wolf, Gunter
    Boettcher, Joachim
    RHEUMATOLOGY INTERNATIONAL, 2011, 31 (10) : 1349 - 1354
  • [9] Feasibility study of semi-automated measurements of finger joint space widths
    Alexander Pfeil
    Julia Sommerfeld
    Rosemarie Fröber
    Gabriele Lehmann
    Ansgar Malich
    Andreas Hansch
    Gunter Wolf
    Joachim Böttcher
    Rheumatology International, 2011, 31 : 1349 - 1354
  • [10] Longitudinal quantification of periarticular demineralization and joint space narrowing in rheumatoid arthritis
    Boettcher, J.
    Pfeil, A.
    Petrovitch, A.
    Kramer, A.
    Lehmann, G.
    Malich, A.
    Kaiser, W. A.
    Wolf, G.
    Hein, G.
    OSTEOPOROSIS INTERNATIONAL, 2006, 17 : S305 - S306