Rapid and quantitative detection of Pythium inflatum by real-time fluorescence loop-mediated isothermal amplification assay

被引:0
作者
Yanyong Cao
Yongqiang Li
Jingjing Li
Lifeng Wang
Zeqiang Cheng
Hao Wang
Zaifeng Fan
Huiyong Li
机构
[1] Henan Academy of Agricultural Sciences,Institute of Cereal Crops
[2] Beijing University of Agriculture,Plant Science and Technology College
[3] China Agricultural University,State Key Laboratory for Agro
来源
European Journal of Plant Pathology | 2016年 / 144卷
关键词
Real-time LAMP; Quantitative detection;
D O I
暂无
中图分类号
学科分类号
摘要
Pythium inflatum is the causal agent of Pythium maize stalk rot, which is one of the most devastating diseases of maize (Zea mays L.). P. inflatum is currently a major concern in global maize production. To the best of our knowledge, no effective resistance to P. inflatum is known in maize, and no effective measures have been reported for the control of this pathogen once maize plants have been infected. Early and accurate detection of P. inflatum is essential to guide maize planting and to protect maize production. A real-time fluorescence loop-mediated isothermal amplification (RealAmp) assay was developed for the rapid quantitative detection of P. inflatum in soil. The detection limit of the RealAmp assay was approximately 0.1 pg/μl plasmid DNA when mixed with extracted soil DNA or 103 spores/g of artificially infested soil. No cross-reactions with other related pathogens were observed. Results of the RealAmp assay for quantifying the genomic DNA of P. inflatum were confirmed by testing with artificially and naturally infested samples. The quantification of the soil-borne pathogen DNA of P. inflatum in naturally infested samples was not significantly different compared with classic real-time PCR (P < 0.05). Additionally, the RealAmp assay could be detected via an improved closed-tube visual detection system by adding SYBR Green I fluorescent dye to the inside of the lid prior to amplification. Consequently, the inhibitory effects of the stain on DNA amplification were avoided. Therefore, the assay could be used more conveniently in the field as a simple, rapid, and effective technique and has the potential to become an alternative tool for detecting and monitoring P. inflatum in the field.
引用
收藏
页码:83 / 95
页数:12
相关论文
共 50 条
  • [21] Colorimetric and Real-Time Loop-Mediated Isothermal Amplification (LAMP) for Detection of Loa loa DNA in Human Blood Samples
    Febrer-Sendra, Begona
    Fernandez-Soto, Pedro
    Crego-Vicente, Beatriz
    Diego, Juan Garcia-Bernalt
    Thuy-Huong Ta-Tang
    Berzosa, Pedro
    Nguema, Rufino
    Ncogo, Policarpo
    Romay-Barja, Maria
    Herrador, Zaida
    Benito, Agustin
    Muro, Antonio
    DIAGNOSTICS, 2022, 12 (05)
  • [22] Detection of Botrytis cinerea by loop-mediated isothermal amplification
    Tomlinson, J. A.
    Dickinson, M. J.
    Boonham, N.
    LETTERS IN APPLIED MICROBIOLOGY, 2010, 51 (06) : 650 - 657
  • [23] Rapid Detection and Quantification of Infectious Hypodermal and Hematopoietic Necrosis Virus in Whiteleg Shrimp Penaeus vannamei Using Real-time Loop-mediated Isothermal Amplification
    Sudhakaran, Raja
    Mekata, Tohru
    Kono, Tomoya
    Supamattaya, Kidchakan
    Linh, Nguyen Thi Hue
    Sakai, Masahiro
    Itami, Toshiaki
    FISH PATHOLOGY, 2008, 43 (04): : 170 - 173
  • [24] Development and Evaluation of a Loop-Mediated Isothermal Amplification Assay for the Detection of Adenovirus 40 and 41
    Ziros, P. G.
    Kokkinos, P. A.
    Allard, A.
    Vantarakis, A.
    FOOD AND ENVIRONMENTAL VIROLOGY, 2015, 7 (03) : 276 - 285
  • [25] Real-time loop-mediated isothermal amplification (LAMP) of mgc2 gene of Mycoplasma gallisepticum
    Ehtisham-ul-Haque, Syed
    Kiran, Madiha
    Waheed, Usman
    Younus, Muhammad
    JOURNAL OF VETERINARY RESEARCH, 2017, 61 (04) : 439 - 444
  • [26] Rapid and sensitive real-time loop meditated isothermal amplification for the detection of Enterocytozoon hepatopenaei of shrimp
    Karthikeyan, K.
    Sharma, Ankith
    Mekata, T.
    Itami, T.
    Sudhakaran, R.
    AQUACULTURE, 2017, 481 : 119 - 123
  • [27] Rapid detection of Salmonella enterica subsp. enterica serovar Thompson by real-time fluorescence loop-mediated isothermal amplification (LAMP) and colorimetric LAMP combined without DNA extraction in the field
    Kim, Eiseul
    Yang, Seung-Min
    Kim, Hae-Yeong
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2023, 182
  • [28] Development and application of a real-time loop-mediated isothermal amplification method for quantification of Acetobacter aceti in red wine
    Zhang, Jingfeng
    Wang, Li
    Shi, Lei
    Chen, Xun
    Liang, Meidan
    Zhao, Lichao
    FEMS MICROBIOLOGY LETTERS, 2020, 367 (19)
  • [29] On-site detection of Xylella fastidiosa in host plants and in "spy insects" using the real-time loop-mediated isothermal amplification method
    Yaseen, Thaer
    Drago, Sandro
    Valentini, Franco
    Elbeaino, Toufic
    Stampone, Giuseppe
    Digiaro, Michele
    D'Onghia, Anna Maria
    PHYTOPATHOLOGIA MEDITERRANEA, 2015, 54 (03) : 488 - 496
  • [30] Loop-Mediated Isothermal Amplification (LAMP) for the Detection of Salmonella in Food
    Kokkinos, P. A.
    Ziros, P. G.
    Bellou, M.
    Vantarakis, A.
    FOOD ANALYTICAL METHODS, 2014, 7 (02) : 512 - 526