Assessment of breath by breath recruitment by electrical impedance tomography in saline lavage lung injury

被引:0
|
作者
J Karsten
H Luepschen
M Grossherr
H Gehring
S Leonhardt
T Meier
机构
[1] University of Lübeck,
[2] Medical Information Technology,undefined
[3] Helmholtz Institute,undefined
来源
Critical Care | / 11卷 / Suppl 2期
关键词
Lung Injury; Acute Lung Injury; Electrical Impedance Tomography; Recruitment Maneuver; Peep Level;
D O I
10.1186/cc5352
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Optimized breath detection algorithm in electrical impedance tomography
    Khodadad, D.
    Nordebo, S.
    Muller, B.
    Waldmann, A.
    Yerworth, R.
    Becher, T.
    Frerichs, I
    Sophodeous, L.
    Van Kaam, A.
    Miedema, M.
    Seifnaraghi, N.
    Bayford, R.
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (09)
  • [2] Monitoring of breath VOCs and electrical impedance tomography under pulmonary recruitment in mechanically ventilated patients
    Brock, Beate
    Kamysek, Svend
    Silz, Josephine
    Trefz, Phillip
    Schubert, Jochen K.
    Miekisch, Wolfram
    JOURNAL OF BREATH RESEARCH, 2017, 11 (01)
  • [3] The Value of Phase Angle in Electrical Impedance Tomography Breath Detection
    Khodadad, Davood
    Nordebo, Sven
    Seifnaraghi, Nima
    Yerworth, Rebecca
    Waldmann, Andreas D.
    Mueller, Beat
    Frerichs, Inez
    van Kaam, Anton
    Miedema, Martijn
    Bayford, Richard
    2018 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS-TOYAMA), 2018, : 1040 - 1043
  • [4] Assessment of Lung Recruitment by Electrical Impedance Tomography and Oxygenation in ARDS Patients
    Yun, Long
    He, Huai-wu
    Moeller, Knut
    Frerichs, Inez
    Liu, Dawei
    Zhao, Zhanqi
    MEDICINE, 2016, 95 (22)
  • [5] Monitoring of recruitment and derecruitment by electrical impedance tomography in a model of acute lung injury
    Kunst, PWA
    de Anda, GV
    Böhm, SH
    Faes, TJC
    Lachmann, B
    Postmus, PE
    de Vries, PMJW
    CRITICAL CARE MEDICINE, 2000, 28 (12) : 3891 - 3895
  • [6] Tidal recruitment assessed by electrical impedance tomography and computed tomography in a porcine model of lung injury
    Muders, Thomas
    Luepschen, Henning
    Zinserling, Joerg
    Greschus, Susanne
    Fimmers, Rolf
    Guenther, Ulf
    Buchwald, Miriam
    Grigutsch, Daniel
    Leonhardt, Steffen
    Putensen, Christian
    Wrigge, Hermann
    CRITICAL CARE MEDICINE, 2012, 40 (03) : 903 - 911
  • [7] Electrical impedance tomography in the clinical assessment of lung volumes following recruitment manoeuvres
    Caruana, Lawrence
    Paratz, Jennifer
    Chang, Angela
    Fraser, John
    PHYSICAL THERAPY REVIEWS, 2011, 16 (01) : 66 - 74
  • [8] ASSESSMENT OF EXTRAVASCULAR LUNG WATER BY ELECTRICAL IMPEDANCE TOMOGRAPHY IN ACUTE LUNG INJURY
    Trepte, C. J. C.
    Phillips, C.
    Sola i Caros, J.
    Adler, A.
    Rapin, M.
    Bohm, S. H.
    Reuter, D. A.
    INTENSIVE CARE MEDICINE, 2013, 39 : S496 - S496
  • [9] Breath-by-breath assessment of acute pulmonary edema using electrical impedance tomography, spirometry and volumetric capnography in a sheep (Ovis Aries) model
    Raisis, Anthea
    Mosing, Martina
    Sacks, Muriel
    Hosgood, Giselle
    Schramel, Johannes
    Blumer, Sarah
    Boehm, Stephan H.
    FRONTIERS IN VETERINARY SCIENCE, 2024, 11
  • [10] Electrical impedance tomography in acute lung injury
    Riera, J.
    Riu, P. J.
    Casan, P.
    Masclans, J. R.
    MEDICINA INTENSIVA, 2011, 35 (08) : 509 - 517