Evaluation of the use of the fourth version FloTrac system in cardiac output measurement before and after cardiopulmonary bypass

被引:0
作者
Sheng-Yi Lin
An-Hsun Chou
Yung-Fong Tsai
Su-Wei Chang
Min-Wen Yang
Pei-Chi Ting
Chun-Yu Chen
机构
[1] Chang Gung Memorial Hospital,Department of Anesthesiology
[2] Linkou Medical Center,Graduate Institute of Clinical Medical Sciences, College of Medicine
[3] Chang Gung University,Clinical Informatics and Medical Statistics Research Center
[4] Chang Gung University College of Medicine,Division of Allergy, Asthma, and Rheumatology, Department of Pediatrics
[5] Chang Gung Memorial Hospital,undefined
来源
Journal of Clinical Monitoring and Computing | 2018年 / 32卷
关键词
FloTrac; Arterial waveform analysis; Cardiac output; Cardiopulmonary bypass; Cohen κ coefficient;
D O I
暂无
中图分类号
学科分类号
摘要
The FloTrac system is a system for cardiac output (CO) measurement that is less invasive than the pulmonary artery catheter (PAC). The purposes of this study were to (1) compare the level of agreement and trending abilities of CO values measured using the fourth version of the FloTrac system (CCO-FloTrac) and PAC-originated continuous thermodilution (CCO-PAC) and (2) analyze the inadequate CO-discriminating ability of the FloTrac system before and after cardiopulmonary bypass (CPB). Fifty patients were included. After exclusion, 32 patients undergoing cardiac surgery with CPB were analyzed. All patients were monitored with a PAC and radial artery catheter connected to the FloTrac system. CO was assessed at 10 timing points during the surgery. In the Bland–Altman analysis, the percentage errors (bias, the limits of agreement) of the CCO-FloTrac were 61.82% (0.16, − 2.15 to 2.47 L min) and 51.80% (0.48, − 1.97 to 2.94 L min) before and after CPB, respectively, compared with CCO-PAC. The concordance rates in the four-quadrant plot were 64.10 and 62.16% and the angular concordance rates (angular mean bias, the radial limits of agreement) in the polar-plot analysis were 30.00% (17.62°, − 70.69° to 105.93°) and 38.63% (− 10.04°, − 96.73° to 76.30°) before and after CPB, respectively. The area under the receiver operating characteristic curve for CCO-FloTrac was 0.56, 0.52, 0.52, and 0.72 for all, ≥ ± 5, ≥ ± 10, and ≥ ± 15% CO changes (ΔCO) of CCO-PAC before CPB, respectively, and 0.59, 0.55, 0.49, and 0.46 for all, ≥ ± 5, ≥ ± 10, and ≥ ± 15% ΔCO of CCO-PAC after CPB, respectively. When CO < 4 L/min was considered inadequate, the Cohen κ coefficient was 0.355 and 0.373 before and after CPB, respectively. The accuracy, trending ability, and inadequate CO-discriminating ability of the fourth version of the FloTrac system in CO monitoring are not statistically acceptable in cardiac surgery.
引用
收藏
页码:807 / 815
页数:8
相关论文
共 81 条
[1]  
Gan TJ(2002)Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery Anesthesiology 97 820-826
[2]  
Wakeling HG(2005)Intraoperative oesophageal Doppler guided fluid management shortens postoperative hospital stay after major bowel surgery Br J Anaesth 95 634-642
[3]  
Noblett SE(2006)Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resection Br J Surg 93 1069-1076
[4]  
Vincent JL(2012)Do we need to monitor cardiac output during major surgery? Anesthesiology 117 1151-1152
[5]  
Fagnoul D(1970)Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter N Engl J Med 283 447-451
[6]  
Swan HJ(2004)Injuries and liability related to central vascular catheters: a closed claims analysis Anesthesiology 100 1411-1418
[7]  
Domino KB(2003)A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients N Engl J Med 348 5-14
[8]  
Sandham JD(1987)A community-wide assessment of the use of pulmonary artery catheters in patients with acute myocardial infarction Chest 92 721-727
[9]  
Gore JM(1990)Use of pulmonary artery catheters in patients with acute myocardial infarction. Analysis of experience in 5,841 patients in the SPRINT Registry. SPRINT Study Group Chest 98 1331-1335
[10]  
Zion MM(1996)The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators JAMA 276 889-897