Automatic panorama with auto-focusing based on image fusion for microscopic imaging system

被引:0
作者
Hulya Dogan
Murat Ekinci
机构
[1] Karadeniz Technical University,Computer Engineering Department
来源
Signal, Image and Video Processing | 2014年 / 8卷
关键词
Auto-focus function; Auto-focusing; Microscope auto-screening; Microscope motorized system; Multi-focus color image fusion; Image stitching;
D O I
暂无
中图分类号
学科分类号
摘要
It is usually desirable from a microscope imaging system to have an efficient auto-focusing and to maintain imaging quality throughout microscopy screening restricted automatically by the specimen borders. This paper presents a novel image fusion-based auto-focusing method and an automatic panorama confined with surroundings of the specimen so as to minimize the auto-scanning time for microscope imaging system. Multi-focus color image fusion is proposed to achieve the auto-focusing task for microscopic imaging. An image sequence is captured by using a microscope eyepiece camera with moving the microscope stage along Z-axis. Several images around a reference image are used to achieve in-focus image, instead of selecting a single image from the sequence. The reference image is an image given highest focus measurement value within the image sequence. Moreover, various evaluation criteria are utilized to analyze the performance of the proposed auto-focus approach on different color models for microscopic imaging. Microscope stage position along the Z-axis is automatically adjusted by image processing-based feedback system to maintain focus during scanning process. In this screening, the in-focus images with overlapped areas on the X–Y axes are stitched together to produce a mosaic image without any seams. In this process, the screening area is automatically constrained with the specimen regions which occupy 20–40 % of the glass surface. An artificial neural network-based learning algorithm is implemented to decide whether the specimen regions are within microscope objective field of view or not. The experimental studies of the proposed method were achieved on an image data set collected from the bright-field microscopy screening for Mycobacterium tuberculosis in specimen of Ziehl–Neelsen-stained sputum smears.
引用
收藏
页码:5 / 20
页数:15
相关论文
共 37 条
[1]  
Santos A(1997)Evaluation of autofocus functions in molecular cytogenetic analysis J. Microsc. 188 264-272
[2]  
Solorzano CO(2011)A novel time-domain focusing method for microscope imaging Proced. Eng. 15 2660-2664
[3]  
Vaquero JJ(2010)Content-based autofocusing in automated microscopy Image Anal. Stereol. 29 173-180
[4]  
Pena JM(2003)Modified fast climbing search auto-focus algorithm with adaptive step size searching technique for digital camera IEEE Trans. Consum. Electron. 49 257-262
[5]  
Malpica N(2010)An efficient auto focus method for digital still camera based on focus value curve prediction model J. Inf. Sci. Eng. 26 1261-1272
[6]  
Pozo F(2008)Real-time face-priority auto focus for digital and cell-phone cameras IEEE Trans. Consum. Electron. 54 1506-1513
[7]  
Liu X(2011)Improved auto-focus search algorithms for CMOS image sensing module J. Inf. Sci. Eng. 27 1377-1393
[8]  
Yu M(2013)Automated image mosaics by non-automated light microscopes: the MicroMas software tool J. Microsc. 252 226-250
[9]  
Wang Y(2013)A method for fast automated microscope image stitching Micron 48 17-25
[10]  
Jiang G(2012)Different image fusion techniques: a critical review Int. J. Mod. Eng. Res. 2 4298-4301