Indoor air quality in elementary schools of Lisbon in spring

被引:0
作者
P. N. Pegas
C. A. Alves
M. G. Evtyugina
T. Nunes
M. Cerqueira
M. Franchi
C. A. Pio
S. M. Almeida
M. C. Freitas
机构
[1] University of Aveiro,Centre for Environmental and Marine Studies, Department of Environment
[2] Nuclear and Technological Institute,undefined
来源
Environmental Geochemistry and Health | 2011年 / 33卷
关键词
Carbon dioxide; Carbon monoxide; Carbonyls; Indoor air quality; Nitrogen dioxide; Schools; Volatile organic compounds;
D O I
暂无
中图分类号
学科分类号
摘要
Analysis of indoor air quality (IAQ) in schools usually reveals higher levels of pollutants than in outdoor environments. The aims of this study are to measure indoor and outdoor concentrations of NO2, speciated volatile organic compounds (VOCs) and carbonyls at 14 elementary schools in Lisbon, Portugal. The investigation was carried out in May–June 2009. Three of the schools were selected to also measure comfort parameters, such as temperature and relative humidity, carbon dioxide (CO2), carbon monoxide (CO), total VOCs, and bacterial and fungal colony-forming units per cubic metre. Indoor concentrations of CO2 in the three main schools indicated inadequate classroom air exchange rates. The indoor/outdoor (I/O) NO2 ratio ranged between 0.36 and 0.95. At the three main schools, the total bacterial and fungal colony-forming units (CFU) in both indoor and outdoor air were above the advised maximum value of 500 CFU/m3 defined by Portuguese legislation. The aromatic compounds benzene, toluene, ethylbenzene and xylenes, followed by ethers, alcohols and terpenes, were usually the most abundant classes of VOCs. In general, the indoor total VOC concentrations were markedly higher than those observed outdoors. At all locations, indoor aldehyde levels were higher than those observed outdoors, particularly for formaldehyde. The inadequate ventilation observed likely favours accumulation of pollutants with additional indoor sources.
引用
收藏
页码:455 / 468
页数:13
相关论文
共 228 条
  • [1] Bhugwant C(2003)Variability of NO Atmospheric Research 66 241-12
  • [2] Hoareau J(2005) in different environments at a moderately polluted island over the southwestern Indian Ocean Indoor Air 15 2-4690
  • [3] Blondeau P(2000)Relationship between outdoor and indoor air quality in eight French schools Atmospheric Environment 34 4683-256
  • [4] Iordache V(2008)Impact of road traffic emissions on air quality of the Lisbon region Indoor Air 18 250-1019
  • [5] Poupard O(2003)Monitoring of volatile organic compounds in non-residential indoor environments Chemosphere 52 1007-234
  • [6] Genin D(2005)Indoor and outdoor carbon monoxide concentration relationships at different microenvironments in the Athens area Indoor Air 15 228-904
  • [7] Allard F(1996)Mouse and cockroach allergens in the dust and air in northeastern United States inner-city public high schools American Industrial Hygiene Association Journal 57 897-64
  • [8] Borrego C(2003)High uptake rate radial diffusive sampler suitable for booth solvent an thermal desorption Indoor Air 13 53-116
  • [9] Tchepel O(2002)Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information Indoor and Built Environment 11 111-1575
  • [10] Barros N(1984)Formaldehyde levels and the factors affecting these levels in homes in Perth, Western Australia British Medical Journal 289 1573-177