Topography and surface energy of dental implants: a methodological approach

被引:0
作者
Tarsis Prado Barbosa
Marina Melo Naves
Helder Henrique Machado Menezes
Pedro Henrique Cunha Pinto
José Daniel Biasoli de Mello
Henara Lillian Costa
机构
[1] Universidade Federal de São João del-Rei,Departamento de Engenharia de Telecomunicações e Mecatrônica
[2] HD Ensinos Odontológicos,Laboratory of Tribology and Materials
[3] Universidade Federal de Uberlândia,Escola de Engenharia
[4] Universidade Federal do Rio Grande,undefined
来源
Journal of the Brazilian Society of Mechanical Sciences and Engineering | 2017年 / 39卷
关键词
Dental implants; Topography; Osseointegration; Laser interferometry; Surface energy; Capillarity;
D O I
暂无
中图分类号
学科分类号
摘要
The surfaces of dental implants are generally modified as an attempt to improve osseointegration. Three surface characteristics of implants are regarded as relevant in the process of bone formation: chemical composition, surface energy and topography. The topography of threaded implants is difficult to measure by conventional equipments with mechanical contact, so optical measuring equipments are preferred. However, implants with large thread angles may have the topography overestimated by the optical measuring equipment due to errors caused by scattering of the reflected light. This paper proposes a new methodology to measure implants with internal thread angle larger than 70° via laser interferometry, positioning the implant with an inclination angle in relation to the equipment base. The results were compared with results for flat discs, produced with the same surface treatment of the implant. Regarding surface energy of implants, most studies use measurements for flat discs, but it is questionable whether the results represent the implant itself. Here, two new methods were proposed to characterize the surface energy of real implants: a qualitative method related to the phenomenon of capillarity and a quantitative method with different liquids of known surface tension. It was found that the topography of the thread flanks is considerably different from the topography of the discs and it is believed that the geometry of the implant influences the surface treatment. The proposed quantitative methodology to analyze the surface energy allowed to detect differences between two commercial implants tested.
引用
收藏
页码:1895 / 1907
页数:12
相关论文
共 88 条
[1]  
Coelho PG(2011)The effect of different implant macrogeometries and surface treatment in early biomechanical fixation: an experimental study in dogs J Mech Behav Biomed Mater 27 1974-1981
[2]  
Granato R(2009)Effects of titanium surface topography on bone integration: a systematic review Clin Oral Implant Res 20 172-184
[3]  
Marin C(2012)Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implants J Mech Behav Biomed Mater 16 169-180
[4]  
Teixeira HS(2007)Requirement for both micron and submicron scale structure for synergistic responses of osteoblasts to substrate surface energy and topography Biomaterials 28 2821-2829
[5]  
Wennerberg A(1996)The role of implant surface characteristics in the healing of bone Crit Rev Oral Biol Med 7 329-345
[6]  
Albrektsson T(2008)Advances in engineered surfaces for functional performance CIRP Ann Manuf Technol 57 750-769
[7]  
Elias CN(2014)A review on the wettability of dental implant surfaces I: theoretical and experimental aspects Acta Biomater 10 2894-2906
[8]  
Rocha FA(2000)Suggested guidelines for the topographic evaluation of implant surfaces Int J Oral Maxillofac Implants 15 331-344
[9]  
Nascimento AL(1998)The effect of titanium plasma-sprayed implants on trabecular bone healing in the goat Biomaterials 19 1093-1099
[10]  
Coelho PG(1996)Characterizing three-dimensional topography of engineering and biomaterial surfaces by confocal laser scanning and stylus techniques Med Eng Phys 18 548-556