Chelating resin preconcentration and Hg(II) assisted elution followed by differential-pulse anodic stripping voltammetry for the determination of Cd, Cu, and Pb in seawater

被引:0
|
作者
Y.-C. Sun
Y.-L. Tu
Jerzy Mierzwa
机构
[1] Department of Nuclear Science,
[2] National Tsing Hua University,undefined
[3] 30043 Hsinchu,undefined
[4] Taiwan,undefined
关键词
Mercury; Nitric Acid; Acid Solution; Reference Material; Analytical Reliability;
D O I
暂无
中图分类号
学科分类号
摘要
A new and efficient Hg(II) back-elution method for the desorption of Cd, Cu, and Pb from Chelex-100 chelating resin was developed. A smaller eluent volume and shorter elution time can be achieved using an Hg(II) containing eluent rather than pure nitric acid. Owing to the remaining Hg(II) ion in the effluent, a mercury thin-film electrode is formed in-situ during the anodic stripping voltammetric determination without any further addition of Hg(II). The results indicate that all the analytes in seawater matrix can be completely adsorbed on Chelex-100 resin from the sample at pH 6.5, and subsequently eluted from the resin with an acid solution of 5 × 10–4 mol/L Hg2+ + 1 mol/L HClO4. The detection limits obtained from the differential-pulse anodic (μg L–1 to ng L–1) stripping voltammetry are at sub-ppb to ppt (μg L–1 to ng L–1) levels permitting to determine Cd, Cu and Pb traces in seawater. The analytical reliability was confirmed by the analysis of the certified reference material CASS-II (open ocean seawater).
引用
收藏
页码:550 / 555
页数:5
相关论文
共 50 条
  • [31] Determination of trace Pb(Ⅱ), Cd(Ⅱ) and Zn(Ⅱ) using differential pulse stripping voltammetry without Hg modification
    LIN Qi
    LIN HongMei
    ZHANG YuanHui
    RONG MingCong
    KE HuiXian
    TANG XinHua
    CHEN Xi
    Science China(Chemistry), 2013, (12) : 1749 - 1756
  • [32] Determination of trace Pb(Ⅱ), Cd(Ⅱ) and Zn(Ⅱ) using differential pulse stripping voltammetry without Hg modification
    LIN Qi
    LIN HongMei
    ZHANG YuanHui
    RONG MingCong
    KE HuiXian
    TANG XinHua
    CHEN Xi
    Science China(Chemistry), 2013, 56 (12) : 1749 - 1756
  • [33] FUMED SILICA FOR THE DIRECT DETERMINATION OF LEAD IN URINE BY DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY
    STAUBER, JL
    FLORENCE, TM
    ANALYTICA CHIMICA ACTA, 1990, 237 (01) : 177 - 180
  • [34] DETERMINATION OF TRACE AMOUNTS OF COPPER IN PALM OIL BY DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY
    WONG, KH
    FUNG, YS
    FUNG, KW
    ANALYST, 1980, 105 (1246) : 30 - 36
  • [35] DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY FOR ULTRATRACE DETERMINATION OF CADMIUM AND LEAD IN ANTARCTIC SNOW
    SCARPONI, G
    BARBANTE, C
    CESCON, P
    ANALUSIS, 1994, 22 (07) : M47 - M50
  • [36] PRECONCENTRATION OF TRACE-METALS IN SEA-WATER MATRIX FOR DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY
    LEE, JD
    LO, JM
    ANALYTICA CHIMICA ACTA, 1994, 287 (03) : 259 - 266
  • [37] DIGESTION-FREE DETERMINATION OF HEAVY-METALS (PH, CD, CU) IN HONEY USING ANODIC-STRIPPING DIFFERENTIAL-PULSE VOLTAMMETRY AND POTENTIOMETRIC STRIPPING ANALYSIS
    LI, YJ
    WAHDAT, F
    NEEB, R
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (07): : 678 - 682
  • [38] SIMULTANEOUS DETERMINATION OF THE TOXIC TRACE-METALS CD, CU, PB AND ZN IN SOILS BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    REDDY, SJ
    VALENTA, P
    NURNBERG, HW
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 313 (05): : 390 - 394
  • [39] MUTUAL INTERFERENCES IN THE DETERMINATION OF ZN(II) AND CU(II) IN SEAWATER BY ANODIC-STRIPPING VOLTAMMETRY
    LAZAR, B
    NISHRI, A
    BENYAAKOV, S
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1981, 125 (02): : 295 - 306
  • [40] POLAROGRAPHY AND DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY OF PB(II)/POLYCARBOXYLATE COMPLEXES
    DIAZCRUZ, JM
    ARINO, C
    ESTEBAN, M
    CASASSAS, E
    VANLEEUWEN, HP
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 344 (1-2): : 119 - 134