A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque

被引:0
作者
Peng Lv
Yuanyuan Dai
Jiang Lin
Weisheng Zhang
Hao Liu
Hui Liu
Xiao Tang
机构
[1] Fudan University and Shanghai Institute of Medical Imaging,Department of Radiology, Zhongshan Hospital
[2] First Affiliated Hospital of Dalian Medical University,Department of Radiology
[3] Fudan University,Department of Vascular Surgery, Zhongshan Hospital
来源
The International Journal of Cardiovascular Imaging | 2017年 / 33卷
关键词
Carotid artery; Plaque; Atherosclerosis; Magnetic resonance imaging;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to compare 3D T2-weighted sampling perfection with application optimized contrast using different flip angle evolutions (T2w SPACE) with conventional 2D T2w turbo-spin echo (TSE) in plaque imaging of carotid artery. 45 patients underwent 3.0-T MRI for carotid arteries imaging. MR sequences included T2w SPACE, T2w TSE, Time of flight (TOF) and T1-weighted (T1w) TSE. The signal intensity of intra-plaque hemorrhage (IPH), lipid-rich necrotic core (LRNC), and loose matrix (LM) were measured and their contrast ratios (CRs) against adjacent muscle were calculated. CRs from T2w SPACE and T2w TSE were compared to each other. CRs of LM, LRNC, and IPH measured on T2w SPACE were 1.74–3.04 (2.44), 0.98–1.66 (1.39), and 1.91–2.93 (2.51), respectively. CRs of LM, LRNC, and IPH on T2w TSE were 1.97–3.41 (2.44), 1.18–1.73 (1.43), and 2.26–3.75 (2.26), respectively. There was no significant difference of CR of the carotid plaques between T2w SPACE and T2w TSE (p = 0.455). Markedly significant differences of CRs were found between LM and LRNC (p < 0.001), and between LRNC and IPH (p < 0.001) on T2w SPACE and T2w TSE. T2w SPACE was comparable with conventional T2w TSE in characterization of carotid plaque.
引用
收藏
页码:395 / 400
页数:5
相关论文
共 79 条
[21]  
Ma L(2005)In vivo quantitative measurement of intact fibrous cap and lipid-rich necrotic core size in atherosclerotic carotid plaque: comparison of high-resolution, contrast-enhanced magnetic resonance imaging and histology Circulation 112 3437-3444
[22]  
Zhao H(2008)N/2 ghosting artifacts: elimination at 3.0-T MR cholangiography with SPACE pulse sequence Radiology 246 589-595
[23]  
Zhao X(2004)Hemorrhage in the atherosclerotic carotid plaque: a high-resolution MRI study Stroke 35 1079-1084
[24]  
Liu X(2007)Reproducibility of high-resolution MRI for the identification and the quantification of carotid atherosclerotic plaque components: consequences for prognosis studies and therapeutic trials Stroke 38 1812-1819
[25]  
Tartari S(undefined)undefined undefined undefined undefined-undefined
[26]  
Rizzati R(undefined)undefined undefined undefined undefined-undefined
[27]  
Righi R(undefined)undefined undefined undefined undefined-undefined
[28]  
Remonda L(undefined)undefined undefined undefined undefined-undefined
[29]  
Senn P(undefined)undefined undefined undefined undefined-undefined
[30]  
Barth A(undefined)undefined undefined undefined undefined-undefined