A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque

被引:0
|
作者
Peng Lv
Yuanyuan Dai
Jiang Lin
Weisheng Zhang
Hao Liu
Hui Liu
Xiao Tang
机构
[1] Fudan University and Shanghai Institute of Medical Imaging,Department of Radiology, Zhongshan Hospital
[2] First Affiliated Hospital of Dalian Medical University,Department of Radiology
[3] Fudan University,Department of Vascular Surgery, Zhongshan Hospital
来源
The International Journal of Cardiovascular Imaging | 2017年 / 33卷
关键词
Carotid artery; Plaque; Atherosclerosis; Magnetic resonance imaging;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to compare 3D T2-weighted sampling perfection with application optimized contrast using different flip angle evolutions (T2w SPACE) with conventional 2D T2w turbo-spin echo (TSE) in plaque imaging of carotid artery. 45 patients underwent 3.0-T MRI for carotid arteries imaging. MR sequences included T2w SPACE, T2w TSE, Time of flight (TOF) and T1-weighted (T1w) TSE. The signal intensity of intra-plaque hemorrhage (IPH), lipid-rich necrotic core (LRNC), and loose matrix (LM) were measured and their contrast ratios (CRs) against adjacent muscle were calculated. CRs from T2w SPACE and T2w TSE were compared to each other. CRs of LM, LRNC, and IPH measured on T2w SPACE were 1.74–3.04 (2.44), 0.98–1.66 (1.39), and 1.91–2.93 (2.51), respectively. CRs of LM, LRNC, and IPH on T2w TSE were 1.97–3.41 (2.44), 1.18–1.73 (1.43), and 2.26–3.75 (2.26), respectively. There was no significant difference of CR of the carotid plaques between T2w SPACE and T2w TSE (p = 0.455). Markedly significant differences of CRs were found between LM and LRNC (p < 0.001), and between LRNC and IPH (p < 0.001) on T2w SPACE and T2w TSE. T2w SPACE was comparable with conventional T2w TSE in characterization of carotid plaque.
引用
收藏
页码:395 / 400
页数:5
相关论文
共 50 条
  • [1] A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque
    Lv, Peng
    Dai, Yuanyuan
    Lin, Jiang
    Zhang, Weisheng
    Liu, Hao
    Liu, Hui
    Tang, Xiao
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (03) : 395 - 400
  • [2] Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
    Murat Ucar
    Nil Tokgoz
    Cagri Damar
    Ayse Gul Alimli
    Fatih Oncu
    Japanese Journal of Radiology, 2015, 33 : 94 - 101
  • [3] Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
    Ucar, Murat
    Tokgoz, Nil
    Damar, Cagri
    Alimli, Ayse Gul
    Oncu, Fatih
    JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (02) : 94 - 101
  • [4] Assessment of the distal anastomosis of coronary artery bypass grafts with a 2D T2-weighted turbo spin echo sequence and correlation to conventional coronary angiography
    Wittlinger, T
    Martinovic, I
    Moritz, A
    Kalden, P
    Kreitner, KF
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 109 (02) : 219 - 225
  • [5] Comparison of 2D Thin Section Dixon, 3D Isotropic SPACE, and 2D T2-Weighted Sequences in Ankle MRI
    Ahn, Tae Ran
    Jeong, Yu Mi
    Jeon, Ji Young
    Park, So Hyun
    Lee, Sheen-Woo
    INVESTIGATIVE MAGNETIC RESONANCE IMAGING, 2022, 26 (04) : 284 - 293
  • [6] T2-Weighted Liver MRI Using the MultiVane Technique at 3T: Comparison with Conventional T2-Weighted MRI
    Kang, Kyung A.
    Kim, Young Kon
    Kim, EunJu
    Jeong, Woo Kyoung
    Choi, Dongil
    Lee, Won Jae
    Jung, Sin-Ho
    Baek, Sun-Young
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (05) : 1038 - 1046
  • [7] High-Resolution 3D versus Standard-Resolution 2D T2-Weighted Turbo Spin Echo MRI for the Assessment of Lumbar Nerve Root Compromise
    Sartoretti, Elisabeth
    Sartoretti, Thomas
    Schwenk, Arpad
    Alfieri, Alex
    Czell, David
    Wyss, Michael
    Wildi, Lukas
    Binkert, Christoph A.
    Sartoretti-Schefer, Sabine
    TOMOGRAPHY, 2022, 8 (01) : 257 - 266
  • [8] Evaluation of diagnostic value and T2-weighted three-dimensional isotropic turbo spin-echo (3D-SPACE) image quality in comparison with T2-weighted two-dimensional turbo spin-echo (2D-TSE) sequences in lumbar spine MR imaging
    Hossein, Jomleh
    Fariborz, Faeghi
    Mehrnaz, Rasteh
    Babak, Rafiei
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2019, 6 : 36 - 41
  • [9] Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT
    G. A. Krombach
    T. Schmitz-Rode
    P. Haage
    E. DiMartino
    A. Prescher
    S. Kinzel
    R. W. Günther
    Neuroradiology, 2004, 46 : 326 - 331
  • [10] Semicircular canal dehiscence:: comparison of T2-weighted turbo spin-echo MRI and CT
    Krombach, GA
    Schmitz-Rode, T
    Haage, P
    DiMartino, E
    Prescher, A
    Kinzel, S
    Günther, RW
    NEURORADIOLOGY, 2004, 46 (04) : 326 - 331