Matching layer design of a 2–2 piezo-composite ultrasonic transducer for biomedical imaging

被引:0
|
作者
Pengfei Lin
Yuanbo Zhu
Dongdong Chen
Chunlong Fei
Chenxi Zheng
Zhaobao Chen
Runcong Wu
Di Li
Shuxiao Zhang
Wei Feng
Zhishui Jiang
Li Wen
Changchun Chai
Yintang Yang
机构
[1] Xidian University,School of Microelectronics
[2] Chinese Academy of Sciences,Shenzhen Institutes of Advanced Technology
[3] University of Chinese Academy of Sciences,undefined
[4] Guangdong JC Technological Innovation Electronics CO.,undefined
[5] LTD,undefined
关键词
Piezo-composite; Matching layers; Ultrasonic transducer; Intelligent optimization; Ultrasonic imaging;
D O I
暂无
中图分类号
学科分类号
摘要
The performance of the piezo-composite transducer is greatly influenced by the matching layers. Based on finite element analysis and artificial intelligence, an optimization design method is proposed to optimize the matching layers of a 2–2 piezo-composite transducer for biomedical imaging. The neural networks are trained by the finite element analysis data to build up the mapping relationship between the thickness of matching layers and the performance. The optimization criteria are established based on the performance (centre frequency, bandwidth, and peak-to-peak voltage) and minimizing the material consumption. The thicknesses of matching layers are optimized by using a particle swarm optimization algorithm. The optimized thicknesses of both matching layers are 49 μm. The optimized centre frequency, bandwidth, and peak-to-peak voltage are 9.1 MHz, 72.5%, and 2.26 V, which can nearly achieve the designed targets (9.5 MHz, 75%, and 2.20 V). According to the optimized thicknesses of matching layers, the fabricated 2–2 piezo-composite transducer exhibits a centre frequency of 9.8 MHz, a bandwidth of 79.6%, and a peak-to-peak voltage of 2.11 V verifies the effectiveness and availability of the proposed method. Then, the piezo-composite transducer is hard-pressed for ultrasonic imaging. The press-focused piezo-composite transducer has an insertion loss of -19.1 dB at 10 MHz, a lateral resolution of 125 μm at 4 mm, and an axial resolution of 132 μm. The good resolution was confirmed by scanning the pig eyeball, which suggests that the 2–2 piezo-composite transducer with optimized matching layers has great potential in biomedical imaging.
引用
收藏
相关论文
共 50 条
  • [21] A Procedure to Extend the Performance of Optimization Methods in Ultrasonic Transducer Matching Layer Design
    Mohammadi, Ali
    Jafari, Mohammad Hassan
    Khanafari, Ali
    2013 13TH IRANIAN CONFERENCE ON FUZZY SYSTEMS (IFSC), 2013,
  • [22] Optimum design of a piezo-composite disk for control of thermoelastic displacement distribution
    Ashida, Fumihiro
    Sakata, Sei-ichiro
    Tauchert, Theodore R.
    Yoshida, Shinji
    JOURNAL OF THERMAL STRESSES, 2007, 30 (06) : 559 - 586
  • [23] Noninvasive and Nonocclusive Blood Pressure Monitoring via a Flexible Piezo-Composite Ultrasonic Sensor
    Peng, Chang
    Chen, Mengyue
    Sim, Hun Ki
    Zhu, Yong
    Jiang, Xiaoning
    IEEE SENSORS JOURNAL, 2021, 21 (03) : 2642 - 2650
  • [24] Experimental investigation on the piezo-composite actuator with piezoelectric single-crystal layer
    Park, Ji Hwan
    Yoon, Bum Soo
    Yoon, Kwang Joon
    ADVANCED COMPOSITE MATERIALS, 2016, 25 (05) : 487 - 496
  • [25] Design and Performance Evaluation of Mini-Lightweight Piezo-Composite Actuators
    Tran, Anh Kim
    Yoon, Kwang Joon
    ADVANCED COMPOSITE MATERIALS, 2009, 18 (04) : 327 - 338
  • [26] A 30-MHz piezo-composite ultrasound array for medical imaging applications
    Ritter, TA
    Shrout, TR
    Tutwiler, R
    Shung, KK
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (02) : 217 - 230
  • [27] Development of a 35-MHz piezo-composite ultrasound array for medical imaging
    Cannata, JM
    Williams, JA
    Zhou, QF
    Ritter, TA
    Shung, KK
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (01) : 224 - 236
  • [28] OPTIMUM STRUCTURE DESIGN OF A MULTILAYER PIEZO-COMPOSITE DISK FOR CONTROL OF THERMAL STRESS
    Elsawaf, Ahmed
    Ashida, Fumihiro
    Sakata, Sei-ichiro
    JOURNAL OF THERMAL STRESSES, 2012, 35 (09) : 805 - 819
  • [29] DEVELOPMENT OF DOUBLE MATCHING LAYER FOR ULTRASONIC POWER TRANSDUCER
    Hwang, Gunn
    Youm, WooSub
    Lee, Sung Q.
    PROCEEDINGS OF THE 23RD INTERNATIONAL CONGRESS ON SOUND AND VIBRATION: FROM ANCIENT TO MODERN ACOUSTICS, 2016,
  • [30] Predicting the losses and the efficiency of a 1-3 piezo-composite transducer through a partial homogeneization method
    Pastor, J
    Richard, C
    Viet, HN
    BOLETIN DE LA SOCIEDAD ESPANOLA DE CERAMICA Y VIDRIO, 2002, 41 (01): : 171 - 176