Uncertainty of carboxyhaemoglobin determination in putrefied blood by headspace gas chromatography

被引:0
作者
Juliusz Adamski
Dariusz Zuba
机构
[1] Institute of Forensic Research,
来源
Accreditation and Quality Assurance | 2016年 / 21卷
关键词
Uncertainty; Carboxyhaemoglobin (COHb); Post-mortem blood analysis; Headspace; Gas chromatography;
D O I
暂无
中图分类号
学科分类号
摘要
The uncertainty of carboxyhaemoglobin (COHb) determination in post-mortem blood samples by headspace gas chromatography with the use of methanizer and flame ionization detector was estimated. Four main components of uncertainty were identified, i.e. calibration, measurement repeatability, standard solutions preparation and sample preparation, and their contributions to the combined uncertainty were determined. The calibration step was the dominating source of uncertainty, counting for more than 39 % of overall variance. The contribution of remaining sources to the combined uncertainty was lower than 31 % (measurement repeatability), 21 % (standards preparation) and 12 % (sample preparation). The calculated absolute expanded uncertainty in samples containing 3.8–82 % mass fraction of COHb ranged between 2.2 % and 2.6 % (coverage factor 2), depending only slightly on the analyte level in the analysed sample.
引用
收藏
页码:279 / 286
页数:7
相关论文
共 45 条
  • [1] Dahms TE(1974)Rapid, accurate technique for determination of carbon monoxide in blood Clin Chem 20 533-537
  • [2] Horwath SM(1986)Determination of carbon monoxide in blood by gas chromatography using a thermal conductivity detector J Forensic Sci 31 133-142
  • [3] Goldbaum LR(1994)Microanalysis of carbon monoxide in blood by head-space capillary gas chromatography J Forensic Sci 39 473-477
  • [4] Chace DH(2004)An accurate method for the determination of carboxyhemoglobin in post-mortem blood using GC-TCD J Anal Toxicol 28 59-62
  • [5] Lappas NT(1968)Determination of carbon monoxide in blood by gas chromatography Clin Chem 17 162-171
  • [6] Van Dam J(1997)Chromatographic determination of carbon monoxide and carboxyhemoglobin by the head-space technique using a catalytic microreactor with FID detector Probl Forensic Sci 36 132-144
  • [7] Daenens P(2010)Rapid determination of carboxyhemoglobin in postmortem blood using fully-automated headspace gas chromatography with methanizer and fid Open Toxicol J 4 21-25
  • [8] Lewis RJ(1993)Estimation of perimortal percent carboxy-heme in nonstandard postmortem specimens using analysis of carbon monoxide by GC/MS and iron by flame atomic absorption spectrophotometry J Anal Toxicol 17 11-13
  • [9] Johnson RD(2012)Accuracy profile validation of a new method for carbon monoxide measurement in the human blood using headspace-gas chromatography-mass spectrometry (HS-GC-MS) J Chrom B 880 125-131
  • [10] Canfield DV(1987)Analysis of carboxyhemoglobin by gas chromatography and multicomponent spectrophotometry compared Clin Chem 33 694-697