Overcoming the Problem of Non-Ideal Liquid Ion Exchanger Selectivity in Microelectrode Ion Flux Measurements

被引:0
|
作者
A. Knowles
S. Shabala
机构
[1] CRC for Sustainable Production Forestry,School of Agricultural Science
[2] University of Tasmania,undefined
来源
关键词
Microelectrodes; Ion fluxes; Selectivity; Liquid ion exchanger; Membrane;
D O I
暂无
中图分类号
学科分类号
摘要
Ion-selective microelectrodes are a powerful tool in studies on various aspects of cell membrane biology in both animal and plant tissues. Further application of this technique is, however, limited to a large extent by the problem of non-ideal selectivity of the liquid ion exchanger used in the preparation of microelectrodes for ion flux measurements. Because of this problem, which is persistent in many commercial liquid ion exchangers, the microelectrode does not discriminate between the ion of interest and other interfering ions (for example, Mg2+ and Ca2+; Na+ and K+), thereby leading to inaccurate concentration readings and, consequently, inaccurate flux calculations. In this work we show that the existing analytical procedure to overcome this problem, using the inverted Nicolsky-Eisenman equation, is inadequate, and suggest an alternative analytical procedure that can be applied directly to the data obtained with commercially available liquid ion exchangers. We show that this alternative procedure allows accurate measurement of ionic concentrations with non-ideal ion-selective microelectrodes in the presence of interfering ions, and illustrate the method by direct experiment using Ca2+ and Mg2+ as a “case study”. Several more examples are given, further illustrating practical applications of the method for study of plant responses to salinity, osmotic and reactive oxygen species stresses.
引用
收藏
页码:51 / 59
页数:8
相关论文
共 50 条
  • [41] Combination of the steric mass action and non-ideal surface solution models for overload protein ion-exchange chromatography
    Raje, P
    Pinto, NG
    JOURNAL OF CHROMATOGRAPHY A, 1997, 760 (01) : 89 - 103
  • [42] Non-ideal operating conditions of the ion source prototype for the ITER neutral beam injector due to thermal deformation of the support structure
    Sartori, E.
    Pavei, M.
    Marcuzzi, D.
    Zaccaria, P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [43] Quantifying inorganic nitrogen uptake capacity among ectomycorrhizal fungal species using MIFE microelectrode ion flux measurements: theory and applications
    Hawkins, B. J.
    Kranabetter, J. M.
    BOTANY, 2017, 95 (10) : 963 - 969
  • [44] DOUBLE BARRELLED K+ SELECTIVE LIQUID ION-EXCHANGER MICROELECTRODE DESIGNED FOR A CONTINUOUS MEASUREMENT OF LOCAL EXTRACELLULAR K+ ACTIVITY IN BRAIN CORTEX IN ANIMALS
    ASTRUP, J
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1975, 35 : 33 - 33
  • [45] Determination of non-ionic and anionic surfactants in industrial products by separation on a weak ion-exchanger, derivatization and liquid chromatography
    Ripoll-Seguer, L.
    Beneito-Cambra, M.
    Herrero-Martinez, J. M.
    Simo-Alfonso, E. F.
    Ramis-Ramos, G.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1320 : 66 - 71
  • [46] Direct Observation of Contact Reaction Induced Ion Migration and its Effect on Non-Ideal Charge Transport in Lead Triiodide Perovskite Field-Effect Transistors
    Zhang, Youcheng
    Ummadisingu, Amita
    Shivanna, Ravichandran
    Tjhe, Dionisius Hardjo Lukito
    Un, Hio-Ieng
    Xiao, Mingfei
    Friend, Richard H.
    Senanayak, Satyaprasad P.
    Sirringhaus, Henning
    SMALL, 2023, 19 (41)
  • [47] Design and Analytical Assessment of Non-Ideal Ion-Sensitive β-MIS-(AlGa)2O3/Ga2O3 High Electron Mobility Transistor
    Ranjan, Ravi
    Kashyap, Nitesh
    Raman, Ashish
    IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2023, 22 : 84 - 90
  • [48] STUDY OF THE MECHANISM OF RESPONSE OF LIQUID ION-EXCHANGER CALCIUM SELECTIVE ELECTRODES .3. MEMBRANE BEHAVIOR UNDER NON-ZERO CURRENT CONDITIONS
    VANMAU, ND
    GAVACH, C
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 97 (02) : 171 - 187
  • [49] Voltammetric simultaneous ion flux measurements platform for Cu2+, Pb2+ and Hg2+ near rice root surface: Utilizing carbon nitride heterojunction film modified carbon fiber microelectrode
    Lv, Hongying
    Teng, Zhenyuan
    Wang, Sicong
    Feng, Ke
    Wang, Xiaoli
    Wang, Chengyin
    Wang, Guoxiu
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 256 : 98 - 106
  • [50] SYNTHESIS AND PROPERTIES OF NON-CYCLIC POLYETHER COMPOUNDS .6. NON-CYCLIC POLYETHERS WITH 2 ORTHO-CARBOXYLPHENYL TERMINAL GROUPS EXHIBITING SELECTIVE TRANSPORT FOR ALKALINE-EARTH METAL-IONS THROUGH LIQUID MEMBRANES - EFFECT OF THE CONCENTRATION OF HYDROXIDE ION ON THE SELECTIVITY
    HIRATANI, K
    SUGIHARA, H
    TAGUCHI, K
    IIO, K
    CHEMISTRY LETTERS, 1983, (11) : 1657 - 1660