Overcoming the Problem of Non-Ideal Liquid Ion Exchanger Selectivity in Microelectrode Ion Flux Measurements

被引:0
|
作者
A. Knowles
S. Shabala
机构
[1] CRC for Sustainable Production Forestry,School of Agricultural Science
[2] University of Tasmania,undefined
来源
关键词
Microelectrodes; Ion fluxes; Selectivity; Liquid ion exchanger; Membrane;
D O I
暂无
中图分类号
学科分类号
摘要
Ion-selective microelectrodes are a powerful tool in studies on various aspects of cell membrane biology in both animal and plant tissues. Further application of this technique is, however, limited to a large extent by the problem of non-ideal selectivity of the liquid ion exchanger used in the preparation of microelectrodes for ion flux measurements. Because of this problem, which is persistent in many commercial liquid ion exchangers, the microelectrode does not discriminate between the ion of interest and other interfering ions (for example, Mg2+ and Ca2+; Na+ and K+), thereby leading to inaccurate concentration readings and, consequently, inaccurate flux calculations. In this work we show that the existing analytical procedure to overcome this problem, using the inverted Nicolsky-Eisenman equation, is inadequate, and suggest an alternative analytical procedure that can be applied directly to the data obtained with commercially available liquid ion exchangers. We show that this alternative procedure allows accurate measurement of ionic concentrations with non-ideal ion-selective microelectrodes in the presence of interfering ions, and illustrate the method by direct experiment using Ca2+ and Mg2+ as a “case study”. Several more examples are given, further illustrating practical applications of the method for study of plant responses to salinity, osmotic and reactive oxygen species stresses.
引用
收藏
页码:51 / 59
页数:8
相关论文
共 50 条
  • [1] Overcoming the problem of non-ideal liquid ion exchanger selectivity in microelectrode ion flux measurements
    Knowles, A
    Shabala, S
    JOURNAL OF MEMBRANE BIOLOGY, 2004, 202 (01): : 51 - 59
  • [2] Non-ideal effects on screening and antiscreening channels for ion-ion collisional excitations in non-ideal plasmas
    Kim, CG
    Jung, YD
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2001, 34 (24) : 5007 - 5016
  • [3] Ion potential in non-ideal dense quantum plasmas
    Moldabekov, Zh. A.
    Groth, S.
    Dornheim, T.
    Bonitz, M.
    Ramazanov, T. S.
    CONTRIBUTIONS TO PLASMA PHYSICS, 2017, 57 (10) : 532 - 538
  • [4] An Improved Transwell Design for Microelectrode Ion-Flux Measurements
    Buchroithner, Boris
    Spurny, Pavel
    Mayr, Sandra
    Heitz, Johannes
    Sivun, Dmitry
    Jacak, Jaroslaw
    Ludwig, Jost
    MICROMACHINES, 2021, 12 (03) : 1 - 9
  • [5] CONTINUOUS MEASUREMENT OF PENTYLENETETRAZOL CONCENTRATION BY A LIQUID ION-EXCHANGER MICROELECTRODE
    WALDEN, J
    LEHMENKUHLER, A
    SPECKMANN, EJ
    WITTE, OW
    JOURNAL OF NEUROSCIENCE METHODS, 1984, 11 (03) : 187 - 192
  • [6] Non-invasive microelectrode ion flux measurements to study adaptive responses of microorganisms to the environment
    Shabala, L
    Ross, T
    McMeekin, T
    Shabala, S
    FEMS MICROBIOLOGY REVIEWS, 2006, 30 (03) : 472 - 486
  • [7] Stability of hydrogen molecular ion in non-ideal classical plasmas
    Das, Biswajit
    Ghoshal, Arijit
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2022, 55 (18)
  • [8] INTERPRETATION OF NON-IDEAL CALIBRATIONS OF ION-SELECTIVE ELECTRODES
    MIDGLEY, D
    ANALYTICAL CHEMISTRY, 1977, 49 (08) : 1211 - 1218
  • [10] Properties of the Positronium Negative Ion Embedded in Non-ideal Classical Plasmas
    Das, Biswajit
    Ghoshal, Arijit
    FEW-BODY SYSTEMS, 2020, 61 (03)