Get 107-2019 Special State Primary Standard of the Unit of Electrical Capacitance in the Frequency Range from 1 to 300 MHz

被引:0
作者
A. M. Shilov
S. D. Zagaynov
A. Ev. Mandrueva
D. V. Ryabchinskiy
Eu. Yu. Uliyanov
机构
[1] The West-Siberian Branch of FSUE “VNIIFTRI”,
[2] Novosibirsk State University,undefined
来源
Measurement Techniques | 2022年 / 65卷
关键词
primary standard; electrical capacitance; reference capacitor; calibration circuit;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents the composition and characteristics of GET 107-2019 Special State Primary Standard of the unit of electrical capacitance in the frequency range of 1–300 MHz. The upper limit of the frequency range for reproducing electric capacitance was expanded to 300 MHz due to the development of a new reference installation with an operating frequency of 300 MHz. The operational principles of the installation and algorithms for processing measurement results are considered. The residual relative systematic error of GET107-2019 ranges from 5·10–5 to 1·10–3 (depending on the operating frequency). The relative standard deviation of the measurement result when reproducing the unit ranges from 3·10–6 to 3·10–4, which exceeds the capabilities of national standards in other countries. An updated State Verification Scheme for measuring electrical capacitance in the frequency range of 1–300 MHz was developed and approved. GET 107-2019, along with its subordinate standards and measuring instruments, is widely used in microand nanoelectronics, biomedicine, radioelectronic industry, instrument engineering, as well as in the development and production of modern materials and equipment.
引用
收藏
页码:549 / 556
页数:7
相关论文
共 48 条
  • [1] Talanov VV(2009)Issledovanie vysokochastotnyh kvarcevyh rezonatorov sreza SC IEEE Trans. Microw. Theor. Tech. 57 1224-1229
  • [2] Schwartz AR(2014)Comparison of impedances of heterogeneous quantities when disseminating electric capacitance unit from the (active) electric resistance unit Sovremennye Informatsionnye i Elektronnye Tekhnologii 2 130-131
  • [3] Goldman EI(2021)Rapid method for measuring dose per pulse of high intensity radiation Komponenty i Tekhnologii 2 44-47
  • [4] Levashova AI(1996)Dvukhpolyusnye ehlementy s fraktal’nym impedansom i ikh primenenie v radiotekhnike i svyazi Meas. Sci. Technol. 7 233-246
  • [5] Levashov SA(2012)Air-filled coaxial lines as absolute impedance standards Meas. Tech. 55 816-825
  • [6] Naryshkina VG(2020)Metodika summirovaniya chastnykh pogreshnostej v oblasti radiotekhnicheskikh izmerenij Metrologija i Priborostroenie 2 20-23
  • [7] Chucheva GV(2021)undefined Nauch. i Obrazovat. Probl. Grazhdansk. Zashhity 2 55-60
  • [8] Demin S(2013)undefined Measurement 46 3796-3801
  • [9] Juzhalkin A(2020)undefined Vest. IzhGTU imeni M. T. Kalashnikova 23 75-105
  • [10] Pashkov S(1999)undefined Science 285 1706-1709