Proficiency Testing in Chemical Analysis of Iron Ore: Comparison of Statistical Methods for Outlier Rejection

被引:0
作者
Sanchita Chakravarty
Ashok Mohanty
Barun Ghosh
Mita Tarafdar
Shankar G. Aggarwal
Prabhat K. Gupta
机构
[1] CSIR-National Metallurgical Laboratory,
[2] CSIR-National Physical Laboratory,undefined
来源
MAPAN | 2014年 / 29卷
关键词
Proficiency testing; Outliers; Iron ore analysis; Statistical methods; Inter laboratory comparison;
D O I
暂无
中图分类号
学科分类号
摘要
Participation in proficiency testing (PT) is an important task to meet the requirements of ISO/IEC 17025 in the area of quality assurance of laboratory results. A PT program in the field of chemical analysis of iron ore was organized by CSIR-National Metallurgical Laboratory, Jamshedpur (nodal laboratory) and CSIR-National Physical Laboratory, New Delhi (PT Coordinator) during November 2011–January 2012. Twenty-two (22) laboratories in India participated in the PT program. The results of participating laboratories were first analyzed to identify the distribution patterns and the presence of outliers. Several parametric and robust statistical methods were used to identify the outliers. Correct outlier rejection is of utmost importance because the choice of the outlier test method influence the consensus value and standard deviation which in turn determine the Z-score of a laboratory result in a PT program. In the present study, five parametric outlier tests were compared: Dixon’s Q test, Grubbs single test, double test, t test, and Z-scores. In addition three robust tests as alternative to parametric tests were chosen: box plot, Huber test and MAD-based test. It was observed that multiple outlier test methods should be used to identify the outliers in a PT program especially when the number of participating laboratories is less. They complement each other and helps give diverse information and better overview of the data set. Among the 22 participating laboratories, Z-scores of 4 laboratories for analysis of total iron fall outside the acceptable limit of ±2. Similarly, for analysis of alumina and silica, five laboratories had unacceptable Z-scores.
引用
收藏
页码:87 / 95
页数:8
相关论文
共 32 条
  • [31] Comparative analysis of calculating sigma metrics by a trueness verification proficiency testing-based approach and an internal quality control data inter-laboratory comparison-based approach
    Li, Runqing
    Wang, Tengjiao
    Gong, Lijun
    Peng, Peng
    Yang, Song
    Zhao, Haibin
    Xiong, Pan
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2019, 33 (09)
  • [32] Comparison of statistical methods for the analysis of patient-reported outcomes (PROs), particularly the Short-Form 36 (SF-36), in randomised controlled trials (RCTs) using standardised effect size (SES): an empirical analysis
    Qian, Yirui
    Walters, Stephen J.
    Jacques, Richard M.
    Flight, Laura
    HEALTH AND QUALITY OF LIFE OUTCOMES, 2025, 23 (01)